The 2W Series Solenoid Valve is a high-performance, two-way two-position diaphragm valve engineered for precision fluid control in demanding industrial environments. Available in both premium Brass and corrosion-resistant Stainless Steel body options, this series is specifically designed for water quality monitoring systems and industrial fluid management, offering seamless integration with water samplers and RO system controllers.

Featuring a direct-action, normally closed configuration, these valves ensure reliable "Energized Open, De-energized Closed" operation. With a wide range of sealing materials including NBR, EPDM, and VITON, the 2W Series provides exceptional versatility across various working media, including liquids, gases, and oils, ensuring long-term stability and leak-proof performance in critical water pollution prevention monitoring setups.

Detailed Parameters

Valve Body MaterialBrass, Stainless SteelInterface RangeThread 1/8''-3'', Flange 1/2''-3''
Working Pressure0-10 kg (0-1.0 MPa)Flow PassageØ2.5mm to 65mm+
Environmental Temp-5°C to +40°COperating Temp Range-5°C to 80°C / 150°C
Voltage OptionsAC220V, AC380V, DC24V, DC12VPower Consumption10W (DN08-10) to 15W (DN40-65)
Working MediumLiquid, Gas, OilWorking FormNormally Closed (Energized Open)

Key Advantages

Premium Durability

Available in Stainless Steel for maximum corrosion resistance in harsh water monitoring environments.

Energy Efficient

Low power consumption design prevents overheating during continuous long-term industrial operation.

High Cost-Effectiveness

Optimized balance of manufacturing quality and pricing for large-scale instrument deployment.

Versatile Sealing

Choice of NBR, EPDM, or VITON to handle temperatures from 80°C up to 150°C.

Flexible Interface

Supports both threaded and flange connections to fit various piping standards (1/8'' to 3'').

Customizable Voltage

Multiple voltage specifications (AC/DC) available to match your specific controller requirements.

Product Gallery

Management Platforms

Precise Flow Control

Accurate medium regulation for water sampling and dosing systems.

Automated Switching

Rapid response solenoid activation for automated monitoring cycles.

Pressure Management

Stable operation within 0-1.0 MPa to ensure system safety.

Leakage Prevention

High-grade sealing materials prevent contamination in water quality tests.

Material Compatibility

Compatible with liquids, gases, and oils for diverse industrial uses.

System Integration

Easy installation with standard thread and flange interfaces.

Investment Return Comparison

Comparison MetricStandard Valve2W Series Premium
Service LifeModerateExtended (High Durability)
Energy CostHigh Power DrawLow Consumption (10W-15W)
Maintenance CycleFrequent Sealing ChangeLong Interval (VITON/EPDM)
Installation SpeedComplex FittingStandardized Quick-Fit
Operational StabilityProne to OverheatingHeat-Resistant Design

Frequently Asked Questions

Q: Which sealing material should I choose for high-temperature water monitoring?

For applications up to 80°C, NBR is suitable. For temperatures up to 120°C, choose EPDM, and for extreme heat up to 150°C, VITON is the recommended sealing material.

Q: How do I ensure the correct installation direction of the solenoid valve?

Always align the medium flow direction with the arrow indicated on the valve body. Additionally, install the valve horizontally with the coil facing upwards (inclination < 30°).

Q: Is a filter necessary before installing the 2W series valve?

Yes, we strongly recommend installing a filter of 80-100 mesh in front of the valve to prevent particles from clogging the coil and ensure smooth operation.

Q: Can these valves be used in explosive industrial environments?

The standard 2W series is not for explosion-proof zones. Please contact us specifically to order the explosion-proof type if your environment requires it.

Q: What is the difference between the Brass and Stainless Steel body options?

Brass is highly cost-effective for general water and gas applications, while Stainless Steel provides superior corrosion resistance for aggressive chemicals or high-purity water monitoring.

Q: What voltage is best for integrating with an RO System Controller?

Most RO controllers use DC24V or AC220V. We offer both, as well as customized voltage options to match your specific electrical control board.

Looking for Precision Fluid Control for Your Water Monitoring System?

Contact Us

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

What's the MOQ?

Down Down

1set sample is available.

What's your price?

Down Down

We quoted based on your products’ code and qty. We can offer different discount depending on qty.

I am not sure of the required product type, how to get quotation?

Down Down

Please tell us the details of your project: Measuring range, temperature, pressure, If need relay control output, 4-20mA or Modbus RS485 output? We will choose suitable product type as per your project details and make quotation for you.

How long is your delivery time?

Down Down

Most of our products are in stock. Generally, we can delivery to you within 2-3 working days. The big order’s delivery time will be determined according to the type and quantity of products ordered.

What’s your term of payment?

Down Down

We accept T/T, Paypal, Western Union, Alipay, credit card, wechat and other suitable payment.
                  
       
                

Related Products

right
right
RO Membrane

RO Membrane

PH-6800

PH-6800

WS-9200/9250

WS-9200/9250

RO-8100

RO-8100

RO- 8200

RO- 8200

ORP-6800

ORP-6800

PH/ORP-600

PH/ORP-600

JIRS-803C

JIRS-803C

Related News

right
right
Rotameter FAQ for small-flow measurement in water treatment

Nov.03,2026

Rotameter FAQ for small-flow measurement in water treatment

Learn how a Rotameter measures fluid flow, where it fits in water-treatment and RO systems, and which accuracy, pressure, and float details to review before ordering.

Choosing WS 9100: Application Fit and Specification Checks

Oct.29,2026

Choosing WS 9100: Application Fit and Specification Checks

Evaluate whether the WS 9100 fits your environmental monitoring project. Review power supply options, temperature-controlled storage, sampling method compatibility, and key specifications before purchasing.

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

Oct.23,2026

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

PH/ORP-6850 FAQ: pH 0–14 and ORP ±1200 mV ranges, ±0.02 pH accuracy, isolated 4–20 mA output, relay alarms, power supply options and panel installation.

Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish