Cl6850 Residual Chlorine Analyzer High Precision Water Quality Suppliers Factory in China

Looking for reliable water quality monitoring? Our Cl-6850 residual chlorine meter is a professional micro-type instrument from a leading China factory. Featuring advanced non-membrane sensors and RS-485 MODBUS communication, we are premier suppliers providing high-sensitivity, stable performance for drinking water plants, swimming pools, and industrial cooling systems.

Product Details

Product Details

Contact Now

Contact Now

Product Details

The Cl-6850 is a professional-grade Residual Chlorine Analyzer designed for high-precision water quality monitoring in industrial and environmental applications. Featuring a large LCD screen and an intuitive English menu, it provides simultaneous real-time display of residual chlorine levels, temperature, and output current, ensuring seamless oversight of water pollution prevention and treatment processes.

Engineered for reliability and stability, the Cl-6850 integrates advanced photoelectric isolation and a robust watchdog function to prevent system crashes. With flexible RS-485 MODBUS communication and adjustable 4-20mA current output, it integrates effortlessly into existing industrial control systems, providing critical data for automated water sampling and chemical dosing operations.

Detailed Parameters

Measuring RangeResidual Chlorine: 0-20.00mg/L(ppm), Temp: 0~60°C Resolution0.01mg/L, 0.1°C
AccuracyBetter than ±1% or ±0.01 mg/L, ±0.5°C Temp CompensationManual/Automatic (0~60°C)
Control Interface2 sets of ON/OFF relays (High/Low alarm), 1 set auto-cleaning Signal OutputOptocoupler isolated 4~20mA signal output
Working Voltage220VAC ±10%, 50/60Hz Protection LevelIP65 Water and Dust Resistant
Dimensions96×105×168 mm (Opening: 92×92mm) Weight0.9Kg

Key Advantages

Industrial Stability

Equipped with a hardware watchdog function to prevent crashes and power-off protection lasting over 10 years.

Precision Monitoring

High-resolution display of 0.01mg/L ensures accurate detection of chlorine levels for strict environmental compliance.

Intelligent Control

Customizable relay hysteresis prevents frequent switching, significantly extending the lifespan of your contactors.

Intuitive Interface

Large screen LCD with an English menu allows for rapid configuration and clear multi-parameter visualization.

Flexible Integration

Supports RS-485 MODBUS protocol and 4-20mA output for seamless connection to PLC and SCADA systems.

Easy Maintenance

Simplified calibration process and factory reset capabilities ensure long-term operational accuracy.

Product Gallery

Management Platforms

Real-time Monitoring

Simultaneous display of chlorine, temperature, and output current for total system transparency.

Automated Calibration

Effortless zero point and slope calibration to maintain high accuracy as sensors age.

Dual-Point Alarm

Configurable High-point and Low-point relays for immediate failure or overflow notification.

Thermal Compensation

Automatic NTC thermistor integration to eliminate temperature-induced measurement errors.

Remote Communication

Partial MODBUS compatibility via RS-485 for centralized water quality data management.

Cleaning Control

Dedicated third group of relays to drive automatic cleaning functions for sensor longevity.

Investment Return Comparison

Comparison FactorStandard MetersCl-6850 Professional
ReliabilityProne to system freezesHardware Watchdog (No Crash)
Relay LifeFrequent switching wearAdjustable Hysteresis Protection
IntegrationBasic analog outputRS-485 MODBUS + Isolated 4-20mA
MaintenanceFrequent manual resets10-Year Power-off Memory
PrecisionBasic temperature correctionAuto NTC Compensation (±0.5°C)

Frequently Asked Questions

Q: How often should the Cl-6850 residual chlorine electrode be calibrated?

While the electrode is factory-calibrated, we recommend periodic calibration of the zero point and slope as the sensor ages to maintain optimal accuracy.

Q: Can this instrument be integrated into a PLC system?

Yes, the Cl-6850 supports both an isolated 4-20mA current output and an RS-485 interface compatible with the MODBUS protocol for easy PLC integration.

Q: What is the purpose of the relay hysteresis setting?

Hysteresis prevents the relays from switching on and off rapidly when the chlorine value fluctuates slightly around the set point, extending the equipment's lifespan.

Q: What is the minimum flow rate required for accurate on-line monitoring?

To ensure accurate and representative measurements, the measured medium should be kept at a constant flow rate with a minimum of 15 cm³/s.

Q: How does the automatic temperature compensation work?

When equipped with an NTC thermistor, the meter automatically measures the water temperature and adjusts the chlorine value to compensate for thermal drift.

Q: What protection level does the Cl-6850 provide for harsh environments?

The instrument features an IP65 protection rating, making it resistant to dust and water splashes, ideal for water treatment plant environments.

Looking for a High-Precision Chlorine Monitoring Solution?

Contact Us

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

What's the MOQ?

Down Down

1set sample is available.

What's your price?

Down Down

We quoted based on your products’ code and qty. We can offer different discount depending on qty.

I am not sure of the required product type, how to get quotation?

Down Down

Please tell us the details of your project: Measuring range, temperature, pressure, If need relay control output, 4-20mA or Modbus RS485 output? We will choose suitable product type as per your project details and make quotation for you.

How long is your delivery time?

Down Down

Most of our products are in stock. Generally, we can delivery to you within 2-3 working days. The big order’s delivery time will be determined according to the type and quantity of products ordered.

What’s your term of payment?

Down Down

We accept T/T, Paypal, Western Union, Alipay, credit card, wechat and other suitable payment.
                  
       
                

Related Products

right
right
RO-8100

RO-8100

ROS-2210

ROS-2210

Rotameter

Rotameter

WS-9300/9350

WS-9300/9350

WS-9200/9250

WS-9200/9250

WS-9200/9250

WS-9200/9250

JIRS-803C

JIRS-803C

JIRS-803C3

JIRS-803C3

Related News

right
right
Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.

Industrial TDS Controller Machine for Water Quality Management

Jun.23,2026

Industrial TDS Controller Machine for Water Quality Management

Maintaining precise water purity is critical for various industrial, agricultural, and domestic applications. A tds controller machine serves as the brain of a water treatment system, continuously monitoring Total Dissolved Solids TDS to ensure that water quality remains within specified limits. Whether you are managing a hydroponic farm, a pharmaceutical lab, or a large-scale reverse osmosis plant, having an automated way to regulate mineral concentrations is essential for efficiency and product consistency. In this guide, we will explore how these machines work and why they are indispensable for modern water management.

Optimize Water Purity with a TDS Controller in RO System

Jun.21,2026

Optimize Water Purity with a TDS Controller in RO System

Maximizing Water Purity: The Role of a TDS Controller in RO System Achieving consistent water quality is the primary goal of any reverse osmosis setup. A tds controller in ro system acts as the brain of the filtration process, monitoring Total Dissolved Solids TDS in real-time to ensure the output meets specific purity standards. Without precise control, users often face the dilemma of either wasting too much water or compromising on the purity of the drinking or process water. By integrating an intelligent controller, you can automate the blending process, extending the life of your membranes while maintaining a perfect balance of minerals.

Optimize Water Quality Using a tds controller for ro Systems

Jun.20,2026

Optimize Water Quality Using a tds controller for ro Systems

Optimizing Water Purity with a TDS Controller for RO Systems Maintaining the ideal balance of minerals in purified water is critical for both industrial processes and residential health. A tds controller for ro acts as the brain of a Reverse Osmosis system, ensuring that Total Dissolved Solids TDS remain within a precise range. Without an effective controller, RO systems can either strip too many essential minerals or allow contaminants to leak through as membranes age. This guide explores how these devices function, their importance in water treatment, and how to choose the right model for your specific needs to ensure consistent water quality.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish