The EC/TDS/RM-6850 is a high-performance industrial controller designed for the precise online monitoring of Conductivity, Total Dissolved Solids (TDS), and Resistivity. Engineered for durability and accuracy, this instrument integrates advanced CPU processing with robust electromagnetic compatibility, making it an essential tool for critical water quality management in demanding industrial environments.

Equipped with a versatile interface and multiple output options—including 4-20mA current signals and Modbus RS485 communication—the EC/TDS/RM-6850 ensures seamless integration into automated control systems. From seawater desalination and reverse osmosis to pharmaceutical and food-grade water treatment, it provides the reliability and precision required to maintain strict water quality standards.

Detailed Parameters

Measuring Range (Cond)0-200uS to 0-600mS (Sensor dependent)TDS Range0-100ppm to 0-99,999ppm
Resistivity Range0-18.25MΩ·cm / 0-18250KΩ·cmAccuracy± 1.5% (Full Scale)
Temperature Comp.0~120 ℃, Automatic (PT1000)Sensor Constants0.01, 0.1, 1.0, 10.0, 30.0 cm-1
Output Signals4-20mA Isolated / Modbus RS485 (Opt)Control OutputHigh/Low Limit relay (3A/250V AC)
Protection GradeIP 65 / Panel Mounted (92x92mm hole)Power SupplyAC 220V / 110V / DC 24V (Optional)

Key Advantages


Industrial Protection

Featuring IP65 protection, MOV, fused AC input, and ESD over-voltage protection for maximum stability.


Intelligent Control

Optional PID control to actuate variable values via 4-20mA output for precise process automation.


High Precision

High-performance CPU and PT1000 automatic temperature compensation ensure laboratory-grade accuracy.


Smart Display

12864 dot matrix LCD with adjustable brightness and power-saving automatic off mode.


Flexible Calibration

Direct input of conductivity constants or probe calibration via known solution values.


Secure Management

Integrated password management system prevents unauthorized parameter modifications.

Product Gallery

Management Platforms

Remote Monitoring

Utilize Modbus RS485 to integrate water quality data into centralized SCADA or PLC systems.

Automated Dosing

4-20mA output enables precise control of dosing pumps for chemical water treatment.

Limit Alarms

Configurable high/low limit relay outputs provide instant alerts for water quality deviations.

Delay Settings

Adjustable alarm delay prevents false triggers caused by momentary signal fluctuations.

Multi-Sensor Support

Compatible with NPT or Flanged sensors for various pipe sizes and installation requirements.

Energy Management

LCD power-saving mode and timing automatic off reduce energy consumption in 24/7 operations.

Investment Return Comparison

FeatureStandard ControllerEC/TDS/RM-6850
Integration CostHigh (External Modules)Low (Integrated Modbus/4-20mA)
Calibration TimeManual/SlowFast (Direct Constant Input)
Maintenance CycleFrequent (Low Protection)Extended (IP65 & ESD Guard)
Operational RiskHigh (Open Access)Low (Password Protected)
System AccuracyStandardHigh (PT1000 Compensation)

Frequently Asked Questions

Q: What is the primary application of the EC/TDS/RM-6850 in water treatment?

It is widely used for online monitoring and control in seawater desalination, reverse osmosis (RO), pharmaceutical water systems, aquaculture, and environmental protection facilities.

Q: How does the device handle temperature fluctuations?

The controller features automatic temperature compensation from 0 to 120℃ using a PT1000 sensor, ensuring accurate readings regardless of thermal changes.

Q: Can the EC/TDS/RM-6850 be integrated into a PLC system?

Yes, it supports both isolated 4-20mA current output and optional Modbus RTU RS485 communication for seamless PLC/SCADA integration.

Q: What sensor connection options are available?

The instrument supports 1/2” NPT (standard), 3/4” NPT (optional), and Flanged connections to accommodate various industrial piping standards.

Q: How is the device protected against electrical surges?

The device includes MOV protection, fused AC inputs, and ESD over-voltage protection to safeguard the electronics from industrial electrical noise and spikes.

Q: Is it possible to calibrate the probe constant directly?

Yes, users can either input the conductivity constant directly or calibrate the probe constant based on the value of a known calibration solution.

Looking for a Professional Water Quality Monitoring Solution?

Contact Us

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

1                  
       
                

Related Products

right
right
RO Membrane

RO Membrane

PH-6800

PH-6800

WS-9200/9250

WS-9200/9250

RO-8100

RO-8100

RO- 8200

RO- 8200

ORP-6800

ORP-6800

PH/ORP-600

PH/ORP-600

JIRS-803C

JIRS-803C

Related News

right
right
Rotameter FAQ for small-flow measurement in water treatment

Nov.03,2026

Rotameter FAQ for small-flow measurement in water treatment

Learn how a Rotameter measures fluid flow, where it fits in water-treatment and RO systems, and which accuracy, pressure, and float details to review before ordering.

Choosing WS 9100: Application Fit and Specification Checks

Oct.29,2026

Choosing WS 9100: Application Fit and Specification Checks

Evaluate whether the WS 9100 fits your environmental monitoring project. Review power supply options, temperature-controlled storage, sampling method compatibility, and key specifications before purchasing.

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

Oct.23,2026

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

PH/ORP-6850 FAQ: pH 0–14 and ORP ±1200 mV ranges, ±0.02 pH accuracy, isolated 4–20 mA output, relay alarms, power supply options and panel installation.

Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish