Looking for reliable water monitoring solutions? JIRS WS-9200/9250 is an industrial-grade automatic portable water sampler from leading China suppliers. Our factory ensures high-precision refrigerated storage, IP55 weatherproof housing, and flexible sampling modes for wastewater and environmental research.

Product Details

Product Details

Contact Now

Contact Now

Product Details

The JIRS WS-9200/9250 series represents the pinnacle of automated water sampling technology, specifically engineered for high-precision environmental monitoring and industrial effluent control. This professional-grade portable sampler combines laboratory-level accuracy with rugged field durability, ensuring the integrity of water samples in the most challenging environments, from municipal wastewater plants to remote watershed management sites.

Designed for versatility and reliability, the WS-9200/9250 features advanced refrigeration and heating modules that maintain sample stability between -30°C and 40°C. With a sophisticated suite of triggering modes—including flow-proportional and rain-gauge activation—this system empowers environmental agencies and research institutions to capture precise snapshots of water quality, ensuring regulatory compliance and accurate pollution source tracking.

Detailed Parameters

Sample Capacity24 Bottles (1000 mL PE)Interface7-inch Color Touchscreen (English)
Sampling Time Points24 Programmable pointsRefrigeration Accuracy(4±2)°C Mechanical Cooling
Sampling Volume10 to 1000 mL (1mL increments)Operating Temp-30°C to 40°C
Pump PerformanceHorizontal ≥80m / Vertical ≥8mProtection RatingIP55 Weatherproof
Power OptionsAC 110V/220V, DC 12V, Car PlugWeight/Dimensions27kg / 711x460x571mm

Key Advantages


Ruggedized Design

IP55 rated protection and extreme temperature modules (-30°C to 40°C) ensure flawless operation in harsh outdoor environments.


Intelligent Sampling

Supports time, flow, level, and rain gauge triggering for comprehensive stormwater and effluent monitoring.


Sample Integrity

Precision mechanical refrigeration (4±2°C) preserves volatile organic compounds and biological contaminants.


Intuitive Control

Large 7-inch color touchscreen with a user-friendly English interface for effortless on-site configuration.


Contamination Control

Automatic pipe rinsing and drainage systems prevent cross-contamination and sedimentation between samples.


Smart Diagnostics

Integrated pump lifetime reminders and failure alarms provide proactive maintenance and data security.

Product Gallery

Management Platforms

SCADA Integration

Seamlessly connects via RS232 and 4-20mA interfaces for centralized industrial monitoring.

Flow Recording

Records instantaneous and cumulative flow data when integrated with external flow meters.

Alarm Archiving

Stores up to 2,000 alarm records for rapid troubleshooting and audit compliance.

Data Logging

Automatic storage of 5,000+ sampling records including time, volume, and results.

Power Protection

Advanced non-volatile memory ensures no data loss during power outages or restarts.

Access Control

Secure password protection prevents unauthorized modification of sampling programs.

Investment Return Comparison

FeatureTraditional Manual SamplingJIRS WS-9200/9250 Series
Labor CostHigh (Constant Manual Site Visits)Low (Automated Remote Collection)
Data AccuracyVariable (Human Error Risk)Precision (Programmable Volume)
Sample QualityPoor (Temperature Degradation)Excellent (Controlled 4±2°C)
ComplianceIntermittent SnapshotsContinuous Regulatory Mapping
Operational RangeLimited by Staff AccessExtreme (-30°C to 40°C)

Frequently Asked Questions

Q: What are the primary applications for water quality monitoring instruments?

These instruments are primarily used in municipal wastewater treatment, industrial effluent control (chemical, pharmaceutical), watershed management, and emergency spill response to ensure environmental safety.

Q: How does the refrigeration system protect water samples?

The mechanical refrigeration system maintains a constant temperature of 4±2°C, which is critical for preventing the degradation of biological contaminants and volatile organic compounds.

Q: Can the sampler operate in freezing winter conditions?

Yes, the WS-9200/9250 is equipped with specialized heating modules for both the refrigerator and pump area, allowing stable operation in temperatures as low as -30°C.

Q: What is flow-proportional sampling and why is it useful?

Flow-proportional sampling triggers a sample based on a specific volume of water passed. This is essential for calculating the total pollutant load in a stream or effluent pipe.

Q: How does the system prevent cross-contamination between bottles?

The sampler uses an automatic pipe rinsing function that flushes the lines before each sampling cycle, ensuring that residues from previous samples are completely removed.

Q: Is it possible to integrate this sampler with a SCADA system?

Absolutely. The unit features RS232 communication and a 4-20mA analog input, making it fully compatible with most modern SCADA and remote monitoring platforms.

Ready to Optimize Your Water Monitoring Strategy?

Contact Us

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

WS-9250-35                  
       
                

Related Products

right
right
RO Membrane

RO Membrane

PH-6800

PH-6800

WS-9200/9250

WS-9200/9250

RO-8100

RO-8100

RO- 8200

RO- 8200

ORP-6800

ORP-6800

PH/ORP-600

PH/ORP-600

JIRS-803C

JIRS-803C

Related News

right
right
Rotameter FAQ for small-flow measurement in water treatment

Nov.03,2026

Rotameter FAQ for small-flow measurement in water treatment

Learn how a Rotameter measures fluid flow, where it fits in water-treatment and RO systems, and which accuracy, pressure, and float details to review before ordering.

Choosing WS 9100: Application Fit and Specification Checks

Oct.29,2026

Choosing WS 9100: Application Fit and Specification Checks

Evaluate whether the WS 9100 fits your environmental monitoring project. Review power supply options, temperature-controlled storage, sampling method compatibility, and key specifications before purchasing.

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

Oct.23,2026

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

PH/ORP-6850 FAQ: pH 0–14 and ORP ±1200 mV ranges, ±0.02 pH accuracy, isolated 4–20 mA output, relay alarms, power supply options and panel installation.

Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.