FL 8860 Flow Meter and Industrial Chlorine Sensor Price Guide

Accurate fluid dynamics measurement is a cornerstone of efficient water quality management and industrial processing. When evaluating the cost of monitoring infrastructure, many procurement managers focus on the chlorine sensor price, yet the operational efficiency of the entire system often depends on the precision of the flow measurement. The FL-8860 wall-mounted transit-time ultrasonic flow meter addresses this need by providing a non-invasive, highly accurate method for liquid flow measurement without the risks associated with pipe cutting or medium contamination. By integrating advanced multi-pulse low-voltage technology, this instrument ensures that industrial operators can maintain strict control over chemical dosing and water treatment processes, directly impacting the longevity and performance of sensitive sensors within the system.

FL 8860 Flow Meter and Industrial Chlorine Sensor Price Guide

Non-Invasive Transit-Time Technology for Contamination-Free Liquid Measurement

The FL-8860 utilizes the transit-time difference method, a sophisticated ultrasonic approach that measures the time it takes for acoustic pulses to travel between two transducers. Unlike traditional flow meters that require direct contact with the fluid, the FL-8860 employs external clamp-on transducers. This design allows the device to be mounted fully outside the pipelines, eliminating the need to stop production or cut into existing infrastructure. This is particularly critical in environments where leakage is a safety hazard or where the measured medium is corrosive or sterile.

By avoiding contact with the measured media, the system removes the risk of medium contamination and pressure drops. The adoption of multi-pulse low-voltage ultrasonic technology enhances the signal-to-noise ratio, delivering a superior accuracy of ±1% and a repeatability of 0.2%. This technical precision ensures that flow rates are captured reliably across a wide range of homogeneous liquids, making it an essential component for facilities that require strict adherence to environmental and safety regulations.

FL 8860 Flow Meter and Industrial Chlorine Sensor Price Guide

Industrial Versatility Across Pipe Materials and Diameters

One of the most significant engineering advantages of the FL-8860 is its extreme compatibility. It is designed to function across a massive range of pipe diameters, from DN15 up to DN6000mm. This scalability makes it suitable for everything from small-scale laboratory dosing lines to massive municipal water mains. Furthermore, the meter is engineered to work with a diverse array of piping materials, including carbon steel, stainless steel, cast iron, PVC, aluminum, and FRP (Fiber Reinforced Plastic), as well as various lined pipes.

To accommodate different installation environments, the FL-8860 supports four optional transducer layouts: V, Z, W, and N. This flexibility ensures that the meter can be installed even in tight spaces or on complex piping networks where standard layouts are impossible. Additionally, the device is built to withstand challenging temperatures, with standard operation from -30 to 90℃ and high-temperature options extending up to 160℃, ensuring stability in HVAC, chemical, and oil processing plants.

Integrated Control Systems and Data Management Capabilities

The FL-8860 is more than a simple sensor; it is a comprehensive all-in-one flow controller. It integrates real-time instantaneous flow monitoring with a cumulative totalizer, enabling precise tracking of liquid volumes over time. For energy management, the device can be connected to a PT100 temperature transducer to perform heat and energy measurements, providing critical data for HVAC and industrial cooling systems. The built-in data storage is remarkably robust, capable of recording flow and energy data for up to 5 years, which is vital for regulatory auditing and performance analysis.

Connectivity is a core strength of this unit. With RS485 MODBUS support, the FL-8860 integrates seamlessly into PLC, DCS, and SCADA systems. For remote locations, it can be paired with a GPRS module to achieve wireless transmission of data. The output options, including 4-20mA analog signals and OCT frequency pulses, allow for immediate triggering of multi-channel alarms or precise batch dosing control, ensuring that water treatment processes remain within safe and efficient parameters.

Technical Specifications and Operational Parameters

Parameter Specification Detail Operational Range Performance Metric
Measurement Principle Transit Time Difference DN15 ~ DN6000mm Accuracy ≤ ±1% FS
Pipe Materials Steel, PVC, FRP, Cast Iron Standard / Lined Pipes Repeatability ≤ 0.2%
Temperature Limits -30~90℃ (Standard) Up to 160℃ (High Temp) Measuring Period: 500ms
Signal Outputs 4-20mA, RS485 MODBUS Max 1000m distance Power Consumption
Data Storage 64 Days / 64 Months Up to 5 Years Total Turbidity ≤ 10000ppm

Optimizing Water Quality Infrastructure for Long-Term Reliability

When designing a water quality monitoring system, the interaction between flow measurement and chemical sensing is paramount. For instance, the effectiveness of a residual chlorine controller depends on a stable and known flow rate to ensure the correct proportion of chemicals is injected. By utilizing the FL-8860, operators can ensure that the volumetric flow is precisely measured, which prevents the over-consumption of reagents and reduces the wear and tear on sensing electrodes. This holistic approach to system design reduces the total cost of ownership by extending the service life of all integrated components.

Reliability in harsh industrial environments is further guaranteed by the dual-balance signal differential receiver/driver circuit. This engineering choice allows the FL-8860 to effectively ignore electromagnetic interference from high-voltage lines, TV towers, and converters. In the context of B2B procurement, this means fewer false alarms and reduced downtime, allowing maintenance teams to focus on preventative care rather than reactive troubleshooting of signal noise.

Strategic Procurement and Customization for Industrial Applications

Selecting the right flow measurement tool requires a balance between technical specifications and procurement goals. Hebei JIRS Import & Export Co., Ltd. specializes in bridging this gap by offering both standardized high-quality products and tailored OEM/ODM solutions. Because every industrial pipeline configuration is unique, the ability to customize transducer selection and communication protocols is essential. Whether the application is in food processing, where hygiene is the priority, or in chemical plants, where corrosion resistance is mandatory, a tailored approach ensures optimal performance.

Beyond the hardware, the value of a partnership lies in professional after-sales support. The complexity of installing ultrasonic transducers—which requires precise alignment and coupling—means that technical guidance is indispensable. By providing dedicated online support for installation and troubleshooting, Hebei JIRS ensures that the high accuracy specifications of the FL-8860 are actually achieved in the field, maximizing the return on investment for the end-user.

Technical FAQ and Selection Guidance

What are the primary advantages of a clamp-on ultrasonic flow meter over an inline meter?

The primary advantages include non-invasive installation, which means no pipes are cut and production does not need to stop. It eliminates the risk of leaks, prevents medium contamination, and avoids pressure drops within the system, making it ideal for sterile or hazardous liquids.

Can the FL-8860 measure flow in pipes made of plastic or composite materials?

Yes, the FL-8860 is compatible with a wide range of materials including PVC, aluminum, and FRP (Fiber Reinforced Plastic), in addition to standard carbon and stainless steel.

How does the device handle liquid turbidity and bubbles?

The FL-8860 can handle liquid turbidity up to 10,000ppm and is designed to remain stable even when tiny bubbles are present in the medium, ensuring reliability in real-world industrial water conditions.

Is it possible to integrate the FL-8860 into an existing SCADA or PLC system?

Absolutely. The device supports RS485 MODBUS communication and 4-20mA analog outputs, allowing it to connect seamlessly with most industrial control systems, DCS, and PLC architectures.

What is the maximum distance for data transmission via cable?

The FL-8860 supports a maximum transmission distance of 1000 meters when using twisted pair cables for its communication interfaces.

Does the FL-8860 support heat or energy measurement?

Yes, by connecting an optional PT100 temperature transducer, the device can calculate and record heat/energy measurement data in addition to volumetric flow.

Technical References and Industry Standards

For enterprises seeking to optimize their water quality infrastructure, integrating high-precision flow measurement is the first step toward total system control. Hebei JIRS is ready to provide the technical expertise and hardware necessary to ensure your operations meet the highest standards of accuracy and reliability.

FL 8860 Flow Meter and Industrial Chlorine Sensor Price Guide

Industrial Instrumentation Specialist

Expert in water quality analysis and industrial flow measurement with extensive experience in deploying ultrasonic sensing technology for B2B environmental monitoring projects.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish