LF55 Series Pressure Switch China Factory and Reliable Suppliers

Looking for high-precision LF55 pressure switches? Our China factory provides industrial-grade SPDT switches for pumps and RO systems. As leading suppliers, we offer durable phosphor bronze and brass construction for maximum safety and reliability.

Product Details

Product Details

Contact Now

Contact Now

Product Details

The LF55 series pressure switch is a high-precision automatic control device engineered to respond instantly to pressure signals, providing critical safety protection and operational automation for industrial systems. Designed for versatility, it is widely utilized in pumps, hydraulic machinery, and specifically optimized for reverse osmosis (RO) water treatment systems to ensure stable pressure management and equipment longevity.

Featuring a robust construction with phosphor bronze bellows and a brass pressure port, the LF55 ensures reliable performance in demanding environments. By leveraging a precision-engineered spring mechanism and SPDT switching, it allows operators to calibrate specific switching points accurately, ensuring that circuits are opened or closed exactly when predefined pressure thresholds are met.

Detailed Parameters

Voltage Rating120V AC / 250V AC Non-induced Current20A / 10A
Full-load Induced Current15A / 8A Momentary Current72A
Sensing ElementPhosphor Bronze Bellows Pressure Port MaterialHigh-Grade Brass
Switch TypeSPDT (Single Pole Double Throw) Thread StandardG 1/4" (Standard) / 7/16-20" (Optional)
Measurement Unitsbar, psig, MPa, Kgf/cm2 Mounting Method4x M4 Screws / Multi-purpose Plate

Key Advantages

Enhanced Safety

Acts as a critical safety fail-safe for hydraulic systems and pumps to prevent over-pressurization.

High Reliability

SPDT switch design ensures stable and consistent contact switching over thousands of cycles.

Precision Tuning

Easily adjustable spring tension allows for precise calibration of the switch point values.

RO System Optimized

Specially engineered for the strict pressure requirements of Reverse Osmosis water treatment.

Material Durability

Phosphor bronze and brass construction provide excellent resistance to wear and corrosion.

Flexible Installation

Supports multiple mounting options including standard brackets and customized capillary models.

Product Gallery

Management Platforms

Range Selection

Wide variety of models from LF5502 to LF5542 covering ranges from -0.5 to 42 bar.

Reset Modes

Available in standard automatic reset and "M" series Manual Reset for higher security.

Custom Fittings

Optional British threads (E), welding models (C), or capillary tubes (S) for custom setups.

Chemical Compatibility

Special "B" model available specifically for Ammonia refrigerant environments.

Quick Mounting

Integrated M4 screw holes and multi-purpose plates for rapid equipment integration.

Scale Versatility

Dual-unit scale plates supporting bar, psig, MPa, and Kgf/cm2 for global standards.

Investment Return Comparison

Performance MetricStandard SwitchesLF55 Pro SeriesBusiness Value
Calibration PrecisionGeneral RangeAdjustable Screw TuningReduced Setup Time
Component LifespanStandard AlloysPhosphor Bronze/BrassLower Replacement Cost
System SafetyBasic On/OffPrecision DifferentialPrevented Equipment Failure
Installation SpeedCustom BracketsStandard M4/PlateLower Labor Expenses
Application RangeLimitedRO / Ammonia / HydraulicUnified Inventory

Frequently Asked Questions

Q: How do I adjust the switching point of the LF55 pressure switch?

By adjusting the adjustment screw, you can modify the spring tension. Screwing it in deeper increases the spring force, which subsequently increases the pressure value at which the switch activates.

Q: Is this pressure switch suitable for water pollution monitoring equipment?

Yes, it is widely used in Reverse Osmosis (RO) systems and other water treatment infrastructures common in water pollution prevention and monitoring.

Q: What is the difference between the LF55 standard and "M" models?

The standard models feature automatic resetting, while the "M" models (e.g., LF5506M) are equipped with a Manual Reset function for enhanced safety control.

Q: Can the LF55 be used with ammonia refrigerants?

Yes, we offer a specific Ammonia refrigerant model. To order this, add the suffix "B" to the model number (e.g., LF5506B).

Q: What installation precautions should I take to avoid damage?

We strongly recommend using two spanners during installation to avoid twisting and damaging the controller body. Use the provided M4 screws or the multi-purpose mounting plate.

Q: Which thread options are available for international projects?

The standard version is G 1/4", but we provide an optional 7/16-20" version and can add British threads (suffix "E") based on custom requirements.

Ready to Optimize Your System Pressure Control?

Contact Us

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

What's the MOQ?

Down Down

1set sample is available.

What's your price?

Down Down

We quoted based on your products’ code and qty. We can offer different discount depending on qty.

I am not sure of the required product type, how to get quotation?

Down Down

Please tell us the details of your project: Measuring range, temperature, pressure, If need relay control output, 4-20mA or Modbus RS485 output? We will choose suitable product type as per your project details and make quotation for you.

How long is your delivery time?

Down Down

Most of our products are in stock. Generally, we can delivery to you within 2-3 working days. The big order’s delivery time will be determined according to the type and quantity of products ordered.

What’s your term of payment?

Down Down

We accept T/T, Paypal, Western Union, Alipay, credit card, wechat and other suitable payment.
                  
       
                

Related Products

right
right
WS-9300/9350

WS-9300/9350

WS-9200/9250

WS-9200/9250

WS-9200/9250

WS-9200/9250

JIRS-803C

JIRS-803C

JIRS-803C3

JIRS-803C3

JIRS-803C4

JIRS-803C4

JIRS-803C5

JIRS-803C5

Soil Sensor

Soil Sensor

Related News

right
right
Industrial RO UV Controller Guide for Pure Water Systems

Jun.13,2026

Industrial RO UV Controller Guide for Pure Water Systems

The Essential Guide to RO UV Controller for Pure Water Systems Achieving ultra-pure water requires more than just filtration; it demands precise management of sterilization and membrane protection. An ro uv controller serves as the central brain of a Reverse Osmosis and Ultraviolet disinfection system, ensuring that water quality remains consistent while protecting expensive components from premature failure. Whether you are managing an industrial plant or a commercial laboratory, understanding how to optimize your control system is key to operational efficiency. In this guide, we will explore the critical role of these controllers in modern water treatment and how they enhance the longevity

Importance of RO Plant Low Pressure Switch for Pump Safety

Jun.11,2026

Importance of RO Plant Low Pressure Switch for Pump Safety

Understanding the Importance of an RO Plant Low Pressure Switch In the complex ecosystem of water purification, ensuring the safety of high-pressure pumps is critical to preventing catastrophic system failure. The ro plant low pressure switch acts as the primary sentinel, monitoring the incoming feed water pressure to ensure the system does not run dry. Operating a Reverse Osmosis RO pump without sufficient water can lead to cavitation, overheating, and permanent membrane damage. This guide explores how these switches function, why they are indispensable for industrial water treatment, and how to select the right one for your specific operational needs.

Optimize Water Purification with RO Microcomputer Controller

Jun.09,2026

Optimize Water Purification with RO Microcomputer Controller

Optimizing Water Purification with an RO Microcomputer Controller In the modern era of water treatment, precision and automation are the keys to efficiency. The ro microcomputer controller serves as the brain of a Reverse Osmosis system, ensuring that every drop of water is processed with mathematical accuracy. By automating complex variables such as pressure, flow rate, and conductivity, these controllers eliminate human error and maximize membrane lifespan. Whether for industrial desalination or high-purity laboratory water, integrating an intelligent control system is no longer an optionit is a necessity for operational excellence.

Guide to Choosing the Right RO Controller for Water Purification

Apr.16,2026

Guide to Choosing the Right RO Controller for Water Purification

Maintaining a high-performance reverse osmosis system requires more than just quality membranes; it demands precise regulation. An ro controller serves as the brain of the entire operation, monitoring critical parameters such as conductivity, temperature, and flow rates to ensure the output water meets stringent purity standards. Without an efficient controller, systems are prone to membrane fouling, inefficient energy use, and inconsistent water quality. In this comprehensive guide, we will explore how these devices optimize water treatment processes and how to select the best model for your specific industrial or commercial needs.

Guide to Water Purity Using RO with TDS Controller Systems

Apr.09,2026

Guide to Water Purity Using RO with TDS Controller Systems

Achieving the perfect balance of mineral content and purity in drinking water is a challenge for many households and industrial facilities. A ro with tds controller offers a sophisticated solution by combining the rigorous filtration of Reverse Osmosis (RO) with the precision of a Total Dissolved Solids (TDS) adjustment system. While standard RO systems remove almost everything, including beneficial minerals, a TDS controller allows users to re-mineralize the water to a desired level. This ensures that the water is not only safe and pure but also tastes better and provides essential nutrients.

Understanding and Optimizing Reverse Osmosis Systems with a Controller

Apr.07,2026

Understanding and Optimizing Reverse Osmosis Systems with a Controller

In the world of water purification, reverse osmosis (RO) systems are a cornerstone for producing high-quality water for various applications, from drinking water to industrial processes. However, an RO system is only as effective as its control system. This is where the reverse osmosis controller comes into play. This critical component manages and optimizes the RO process, ensuring efficient operation, water quality, and system longevity.

Understanding the Vital Role of an RO System Controller for Optimal Performance

Apr.04,2026

Understanding the Vital Role of an RO System Controller for Optimal Performance

Reverse Osmosis (RO) systems are critical for purifying water across various industries, from residential applications to large-scale industrial processes. At the heart of a well-functioning RO system lies the RO system controller. This intelligent device monitors and regulates all key parameters of the RO process, ensuring optimal performance, efficiency, and water quality. This article delves into the functionalities, benefits, and selection criteria for choosing the right RO system controller, particularly focusing on those offered by Watequipments. Understanding its role is crucial for maximizing the lifespan and effectiveness of your RO investment.

Smart Water Treatment Solutions Using PH ORP Controller Systems

Mar.24,2026

Smart Water Treatment Solutions Using PH ORP Controller Systems

In modern water treatment and industrial fluid management, maintaining precise chemical balance is essential for safety, efficiency, and regulatory compliance.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.