LF55 Series Pressure Switch China Factory and Reliable Suppliers

Looking for high-precision LF55 pressure switches? Our China factory provides industrial-grade SPDT switches for pumps and RO systems. As leading suppliers, we offer durable phosphor bronze and brass construction for maximum safety and reliability.

Product Details

Product Details

Contact Now

Contact Now

Product Details

The LF55 series pressure switch is a high-precision automatic control device engineered to respond instantly to pressure signals, providing critical safety protection and operational automation for industrial systems. Designed for versatility, it is widely utilized in pumps, hydraulic machinery, and specifically optimized for reverse osmosis (RO) water treatment systems to ensure stable pressure management and equipment longevity.

Featuring a robust construction with phosphor bronze bellows and a brass pressure port, the LF55 ensures reliable performance in demanding environments. By leveraging a precision-engineered spring mechanism and SPDT switching, it allows operators to calibrate specific switching points accurately, ensuring that circuits are opened or closed exactly when predefined pressure thresholds are met.

Detailed Parameters

Voltage Rating120V AC / 250V AC Non-induced Current20A / 10A
Full-load Induced Current15A / 8A Momentary Current72A
Sensing ElementPhosphor Bronze Bellows Pressure Port MaterialHigh-Grade Brass
Switch TypeSPDT (Single Pole Double Throw) Thread StandardG 1/4" (Standard) / 7/16-20" (Optional)
Measurement Unitsbar, psig, MPa, Kgf/cm2 Mounting Method4x M4 Screws / Multi-purpose Plate

Key Advantages

Enhanced Safety

Acts as a critical safety fail-safe for hydraulic systems and pumps to prevent over-pressurization.

High Reliability

SPDT switch design ensures stable and consistent contact switching over thousands of cycles.

Precision Tuning

Easily adjustable spring tension allows for precise calibration of the switch point values.

RO System Optimized

Specially engineered for the strict pressure requirements of Reverse Osmosis water treatment.

Material Durability

Phosphor bronze and brass construction provide excellent resistance to wear and corrosion.

Flexible Installation

Supports multiple mounting options including standard brackets and customized capillary models.

Product Gallery

Management Platforms

Range Selection

Wide variety of models from LF5502 to LF5542 covering ranges from -0.5 to 42 bar.

Reset Modes

Available in standard automatic reset and "M" series Manual Reset for higher security.

Custom Fittings

Optional British threads (E), welding models (C), or capillary tubes (S) for custom setups.

Chemical Compatibility

Special "B" model available specifically for Ammonia refrigerant environments.

Quick Mounting

Integrated M4 screw holes and multi-purpose plates for rapid equipment integration.

Scale Versatility

Dual-unit scale plates supporting bar, psig, MPa, and Kgf/cm2 for global standards.

Investment Return Comparison

Performance MetricStandard SwitchesLF55 Pro SeriesBusiness Value
Calibration PrecisionGeneral RangeAdjustable Screw TuningReduced Setup Time
Component LifespanStandard AlloysPhosphor Bronze/BrassLower Replacement Cost
System SafetyBasic On/OffPrecision DifferentialPrevented Equipment Failure
Installation SpeedCustom BracketsStandard M4/PlateLower Labor Expenses
Application RangeLimitedRO / Ammonia / HydraulicUnified Inventory

Frequently Asked Questions

Q: How do I adjust the switching point of the LF55 pressure switch?

By adjusting the adjustment screw, you can modify the spring tension. Screwing it in deeper increases the spring force, which subsequently increases the pressure value at which the switch activates.

Q: Is this pressure switch suitable for water pollution monitoring equipment?

Yes, it is widely used in Reverse Osmosis (RO) systems and other water treatment infrastructures common in water pollution prevention and monitoring.

Q: What is the difference between the LF55 standard and "M" models?

The standard models feature automatic resetting, while the "M" models (e.g., LF5506M) are equipped with a Manual Reset function for enhanced safety control.

Q: Can the LF55 be used with ammonia refrigerants?

Yes, we offer a specific Ammonia refrigerant model. To order this, add the suffix "B" to the model number (e.g., LF5506B).

Q: What installation precautions should I take to avoid damage?

We strongly recommend using two spanners during installation to avoid twisting and damaging the controller body. Use the provided M4 screws or the multi-purpose mounting plate.

Q: Which thread options are available for international projects?

The standard version is G 1/4", but we provide an optional 7/16-20" version and can add British threads (suffix "E") based on custom requirements.

Ready to Optimize Your System Pressure Control?

Contact Us

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

What's the MOQ?

Down Down

1set sample is available.

What's your price?

Down Down

We quoted based on your products’ code and qty. We can offer different discount depending on qty.

I am not sure of the required product type, how to get quotation?

Down Down

Please tell us the details of your project: Measuring range, temperature, pressure, If need relay control output, 4-20mA or Modbus RS485 output? We will choose suitable product type as per your project details and make quotation for you.

How long is your delivery time?

Down Down

Most of our products are in stock. Generally, we can delivery to you within 2-3 working days. The big order’s delivery time will be determined according to the type and quantity of products ordered.

What’s your term of payment?

Down Down

We accept T/T, Paypal, Western Union, Alipay, credit card, wechat and other suitable payment.
                  
       
                

Related Products

right
right
RO Membrane

RO Membrane

PH-6800

PH-6800

WS-9200/9250

WS-9200/9250

RO-8100

RO-8100

RO- 8200

RO- 8200

ORP-6800

ORP-6800

PH/ORP-600

PH/ORP-600

JIRS-803C

JIRS-803C

Related News

right
right
Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.

Industrial TDS Controller Machine for Water Quality Management

Jun.23,2026

Industrial TDS Controller Machine for Water Quality Management

Maintaining precise water purity is critical for various industrial, agricultural, and domestic applications. A tds controller machine serves as the brain of a water treatment system, continuously monitoring Total Dissolved Solids TDS to ensure that water quality remains within specified limits. Whether you are managing a hydroponic farm, a pharmaceutical lab, or a large-scale reverse osmosis plant, having an automated way to regulate mineral concentrations is essential for efficiency and product consistency. In this guide, we will explore how these machines work and why they are indispensable for modern water management.

Optimize Water Purity with a TDS Controller in RO System

Jun.21,2026

Optimize Water Purity with a TDS Controller in RO System

Maximizing Water Purity: The Role of a TDS Controller in RO System Achieving consistent water quality is the primary goal of any reverse osmosis setup. A tds controller in ro system acts as the brain of the filtration process, monitoring Total Dissolved Solids TDS in real-time to ensure the output meets specific purity standards. Without precise control, users often face the dilemma of either wasting too much water or compromising on the purity of the drinking or process water. By integrating an intelligent controller, you can automate the blending process, extending the life of your membranes while maintaining a perfect balance of minerals.

Optimize Water Quality Using a tds controller for ro Systems

Jun.20,2026

Optimize Water Quality Using a tds controller for ro Systems

Optimizing Water Purity with a TDS Controller for RO Systems Maintaining the ideal balance of minerals in purified water is critical for both industrial processes and residential health. A tds controller for ro acts as the brain of a Reverse Osmosis system, ensuring that Total Dissolved Solids TDS remain within a precise range. Without an effective controller, RO systems can either strip too many essential minerals or allow contaminants to leak through as membranes age. This guide explores how these devices function, their importance in water treatment, and how to choose the right model for your specific needs to ensure consistent water quality.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish