The ORP-TRA-600 is a high-precision Oxidation-Reduction Potential (ORP) transmitter designed for rigorous water quality monitoring in industrial and environmental applications. Engineered for stability and accuracy, this instrument provides real-time redox potential measurement, ensuring precise control over disinfection, wastewater treatment, and chemical processing through a professional-grade interface and robust sensor compatibility.

Featuring a wide measurement range from -1000mV to +1000mV and multiple output options including 4-20mA and Modbus RS485, the ORP-TRA-600 integrates seamlessly into automated PLC systems. Its intuitive one-point calibration system and industrial-standard DIN installation make it an ideal choice for engineers seeking a reliable, low-maintenance solution for water pollution prevention and monitoring.

Detailed Parameters

Measurement Range-1000mV ~ +1000mVResolution/Accuracy0.2 mV / ±0.2 mV
Display Mode3½ LCD Digital DisplayCalibration ModeOne-point (Automatic Identification)
Temperature Comp.Manual 0~120℃Pressure Resistance≤0.4Mpa / 0~0.5MPa (Electrodes)
Output Signal4-20mA / Modbus RS485 (Optional)Control OutputMaxi. and Mini. Contact Points (3A/AC250V)
Power SupplyDC-24V or DC-12V (0.5A)Installation ModeStandard DIN Rail Installation

Key Advantages


Industrial Durability

Built with high-grade materials to withstand pressure up to 0.4Mpa and flow velocities up to 3m/s in harsh environments.


Efficient Calibration

Simplified one-point calibration with automatic solution identification reduces downtime and operator error.


High Precision

Professional 0.2mV resolution ensures extreme accuracy for sensitive redox potential monitoring tasks.


Smart Integration

Supports both analog 4-20mA and digital Modbus RS485 for flexible integration with SCADA and PLC systems.


Clear Visualization

Equipped with a high-contrast 3½ LCD screen for instant reading of critical water quality parameters.


Flexible Alarm Logic

Integrated high/low limit relay alarm outputs allow for immediate autonomous system response.

Product Gallery

Management Platforms

Remote Data Monitoring

Utilize RS485 Modbus output for centralized real-time tracking of ORP levels across multiple stations.

Automated Process Control

Configure high/low limit relays to trigger dosing pumps or valves automatically based on redox values.

Critical Alarm Logic

Set custom delay timers and alarm thresholds to prevent nuisance trips while ensuring safety.

Calibration Management

Standardized one-point calibration ensures consistent measurement across different instrument sets.

System Integration

Compatible with standard 4-20mA analog inputs for legacy PLC and DCS system upgrades.

Electrode Maintenance

Professional maintenance protocols for PTFE and glass bulbs to extend sensor lifecycle.

Investment Return Comparison

Evaluation MetricConventional SensorsORP-TRA-600 System
Calibration EffortManual & Time-ConsumingRapid One-Point Auto-ID
Signal ReliabilityProne to InterferenceShielded Cables & Stable Modbus
Installation TimeCustom Mounting RequiredStandard DIN Rail Fast-Fit
Maintenance CycleFrequent Manual CleaningExtended Lifecycle w/ PTFE
Operational RiskDelayed Alarm ResponseInstant Relay-Based Control

Frequently Asked Questions

Q: How often should the ORP-TRA-600 electrode be calibrated?

Calibration frequency depends on the water quality. We recommend a regular check monthly or whenever a significant shift in process conditions occurs to ensure the ±0.2 mV accuracy is maintained.

Q: What is the difference between 4-20mA and RS485 outputs for water monitoring?

4-20mA is a standard analog signal ideal for simple distance transmission to a PLC. RS485 Modbus is a digital protocol allowing multiple devices to share one cable and provide more detailed diagnostic data.

Q: Can this instrument be used in high-pressure water pipelines?

Yes, the electrodes are designed to withstand compression resistance up to 0.5MPa, and the system is rated for pressure ≤0.4Mpa, making it suitable for most industrial piping.

Q: How do I clean the ORP sensor if it becomes contaminated with grease?

For grease or oily deposits, use a surface active agent. For calcium or metal precipitates, a 10% hydrochloric acid solution is recommended. Always rinse with clean water after cleaning.

Q: What should I do if the display shows "ERR" during calibration?

An "ERR" message indicates a calibration failure. First, ensure the electrode is submerged in the correct buffer solution for 5 minutes. If it persists, the electrode may be damaged and requires replacement.

Q: Is the ORP-TRA-600 suitable for wastewater pollution prevention?

Absolutely. It is specifically engineered for the water pollution prevention and control industry, providing the critical redox data needed to manage aeration and chemical oxidation processes.

Ready to Optimize Your Water Quality Monitoring?

Contact Us

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

                  
       
                

Related Products

right
right
RO Membrane

RO Membrane

PH-6800

PH-6800

WS-9200/9250

WS-9200/9250

RO-8100

RO-8100

RO- 8200

RO- 8200

ORP-6800

ORP-6800

PH/ORP-600

PH/ORP-600

JIRS-803C

JIRS-803C

Related News

right
right
Rotameter FAQ for small-flow measurement in water treatment

Nov.03,2026

Rotameter FAQ for small-flow measurement in water treatment

Learn how a Rotameter measures fluid flow, where it fits in water-treatment and RO systems, and which accuracy, pressure, and float details to review before ordering.

Choosing WS 9100: Application Fit and Specification Checks

Oct.29,2026

Choosing WS 9100: Application Fit and Specification Checks

Evaluate whether the WS 9100 fits your environmental monitoring project. Review power supply options, temperature-controlled storage, sampling method compatibility, and key specifications before purchasing.

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

Oct.23,2026

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

PH/ORP-6850 FAQ: pH 0–14 and ORP ±1200 mV ranges, ±0.02 pH accuracy, isolated 4–20 mA output, relay alarms, power supply options and panel installation.

Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish