The PC-6850 is a professional-grade, double-channel PH/ORP Controller engineered for high-precision water quality monitoring. Designed specifically for industrial water pollution prevention and environmental monitoring, this robust instrument provides simultaneous measurement and control of PH and Oxidation-Reduction Potential (ORP), ensuring your water treatment processes remain within strict regulatory and operational limits.

Featuring a high-resolution 128 64 dot matrix LCD and flexible output options, including Modbus RS485 and dual 4-20mA signals, the PC-6850 integrates seamlessly into automated PLC systems. Whether deployed in wastewater treatment plants or chemical processing facilities, its advanced temperature compensation and three-point calibration system guarantee unmatched accuracy and long-term stability in demanding environments.

Detailed Parameters

Measurement RangePH: 0.00~14.00 pH | ORP: -1200~+1200 mVMeasurement AccuracyPH: ±0.1 pH | ORP: ±2mV
Temp. Compensation0–100 ℃ (Manual/Auto: NTC 10k, PT100, PT1000)Operating Temp.0~60℃ (Normal) / 0~100℃ (High Temp Sensor)
Sensor CompatibilityTwo/Three Composite PH sensor, ORP sensorCalibrationThree Point Calibration (4.00, 6.86, 9.18)
Output SignalDouble 4-20mA Isolated (Max resistance 750Ω)Control SignalHigh/Low Limit Alarm Contact (3A/250V AC, NO)
CommunicationModbus RS485 (Baud: 2400, 4800, 9600)Power SupplyAC220V±10% (Std), AC110V, DC24V, 12VDC (Opt)

Key Advantages


High Precision

Delivers professional accuracy with ±0.1 pH and ±2mV ORP readings for critical process control.


Thermal Stability

Automatic temperature compensation up to 100°C ensures consistent data across temperature fluctuations.


Dual Channel Control

Simultaneous monitoring of PH and ORP allows for comprehensive water quality management in one unit.


Clear Visualization

Equipped with a 12864 dot matrix LCD for intuitive real-time data display and easy navigation.


Flexible Integration

Supports RS485 Modbus and isolated 4-20mA outputs for seamless PLC and SCADA integration.


Industrial Design

Panel-mounted (92x92mm hole) design built for rugged industrial environments and easy installation.

Product Gallery

Management Platforms

Automated Dosing

Link the control relay to dosing pumps for automatic PH adjustment based on set limits.

Remote Monitoring

Utilize RS485 Modbus communication to track water quality from a central control room.

Threshold Alarms

Configure high and low limit alarms to prevent chemical overflows or water acidification.

PLC Integration

Standard 4-20mA outputs allow for seamless connection to any industrial PLC system.

Precise Calibration

Three-point calibration powder ensures the sensor remains accurate over long operation periods.

Power Versatility

Optional power supplies (DC24V/12V) allow for flexible installation in various power grids.

Investment Return Comparison

FeatureStandard ControllersPC-6850 System
Measurement ChannelsSingle ParameterDual (PH & ORP)
Calibration MethodTwo-point / ManualProfessional Three-point
ConnectivityAnalog OnlyRS485 Modbus + Analog
Temp. CompensationBasic/FixedDynamic (NTC/PT100/PT1000)
Operational LifeFrequent RecalibrationHigh Stability / Long Lifecycle

Frequently Asked Questions

Q: How does the PC-6850 handle temperature variations in water?

The PC-6850 features advanced temperature compensation (0–100 ℃) supporting NTC 10k, PT100, and PT1000 RTD sensors to ensure PH and ORP readings remain accurate regardless of water temperature changes.

Q: Can this controller be integrated into a central SCADA system?

Yes, it is fully compatible with SCADA and PLC systems via its Modbus RS485 communication interface (baud rates 2400, 4800, 9600) and dual isolated 4-20mA signal outputs.

Q: What is included in the PC-6850 full set?

The full set includes one PH/ORP controller, one PH and ORP sensor, an operation manual, a qualified certificate, a pair of controller fixed clamps, and a set of three calibration powder bags.

Q: How often should the three-point calibration be performed?

Calibration frequency depends on the water quality and sensor fouling; however, using the provided 4.00, 6.86, and 9.18 powders monthly is recommended for industrial water pollution monitoring to maintain ±0.1 pH accuracy.

Q: Is the 4-20mA output signal isolated?

Yes, the PC-6850 provides isolated and reversible transferable double 4-20mA signal outputs with a maximum circle resistance of 750Ω, preventing electrical interference in industrial settings.

Q: What installation dimensions are required for the panel mount?

The overall dimensions are 96×96×130mm, and the required hole dimensions for panel embedding are 92×92mm.

Ready to Optimize Your Water Quality Monitoring?

Contact Us

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

PC-6850- full set                  
       
                

Related Products

right
right
RO Membrane

RO Membrane

PH-6800

PH-6800

WS-9200/9250

WS-9200/9250

RO-8100

RO-8100

RO- 8200

RO- 8200

ORP-6800

ORP-6800

PH/ORP-600

PH/ORP-600

JIRS-803C

JIRS-803C

Related News

right
right
Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.

Industrial TDS Controller Machine for Water Quality Management

Jun.23,2026

Industrial TDS Controller Machine for Water Quality Management

Maintaining precise water purity is critical for various industrial, agricultural, and domestic applications. A tds controller machine serves as the brain of a water treatment system, continuously monitoring Total Dissolved Solids TDS to ensure that water quality remains within specified limits. Whether you are managing a hydroponic farm, a pharmaceutical lab, or a large-scale reverse osmosis plant, having an automated way to regulate mineral concentrations is essential for efficiency and product consistency. In this guide, we will explore how these machines work and why they are indispensable for modern water management.

Optimize Water Purity with a TDS Controller in RO System

Jun.21,2026

Optimize Water Purity with a TDS Controller in RO System

Maximizing Water Purity: The Role of a TDS Controller in RO System Achieving consistent water quality is the primary goal of any reverse osmosis setup. A tds controller in ro system acts as the brain of the filtration process, monitoring Total Dissolved Solids TDS in real-time to ensure the output meets specific purity standards. Without precise control, users often face the dilemma of either wasting too much water or compromising on the purity of the drinking or process water. By integrating an intelligent controller, you can automate the blending process, extending the life of your membranes while maintaining a perfect balance of minerals.

Optimize Water Quality Using a tds controller for ro Systems

Jun.20,2026

Optimize Water Quality Using a tds controller for ro Systems

Optimizing Water Purity with a TDS Controller for RO Systems Maintaining the ideal balance of minerals in purified water is critical for both industrial processes and residential health. A tds controller for ro acts as the brain of a Reverse Osmosis system, ensuring that Total Dissolved Solids TDS remain within a precise range. Without an effective controller, RO systems can either strip too many essential minerals or allow contaminants to leak through as membranes age. This guide explores how these devices function, their importance in water treatment, and how to choose the right model for your specific needs to ensure consistent water quality.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish