PHTRA600 Industrial pH Transmitter High Precision China Factory Suppliers

The PH-TRA-600 is a high-precision online pH transmitter from leading China factory suppliers. Designed for industrial wastewater and chemical processing, it features 3-point auto-calibration, 4-20mA/RS485 outputs, and dual alarm control for reliable environmental protection.

Product Details

Product Details

Contact Now

Contact Now

Product Details

The PH-TRA-600 is a high-precision industrial pH transmitter engineered for rigorous water quality monitoring in wastewater treatment, chemical processing, and environmental protection systems. Featuring a robust design and a clear 3½ LCD display, it ensures real-time, accurate pH measurement ranging from 0.000 to 14.00pH, providing critical data for maintaining chemical balance and regulatory compliance in water pollution prevention.

Designed for seamless integration, the PH-TRA-600 supports multiple output protocols including 4-20mA current and Modbus RS485, allowing for efficient remote monitoring and automated control. With its specialized three-point automatic calibration and versatile temperature compensation options, this instrument delivers professional-grade stability and reliability even in demanding industrial environments with flow velocities up to 3m/s.

Detailed Parameters

Measurement Range0.000 ~ 14.00 pHResolution / Accuracy0.02 pH / ±0.1 pH
Display Mode3½ LCD DisplayCalibration Mode3-Point Auto-Identification
Temp. Compensation0 ~ 120℃ (Manual/Auto)Output Signal4-20mA / Modbus RS485
Power SupplyDC 24V or DC 12V (Optional)Operating Temp/Humid0~50℃ / ≤85% RH
Installation ModeDIN Rail InstallationExternal Dimensions927659mm (H x W x D)

Key Advantages


Industrial Durability

Built to withstand harsh environments with electrode compression resistance up to 0.5MPa and high-grade materials.


Stable Measurement

Reliable performance in flowing water with velocities up to 3m/s and a wide temperature compensation range.


Precision Calibration

Simplified 3-point calibration process with automatic solution recognition to ensure long-term accuracy.


Smart Integration

Dual output options (4-20mA and RS485) for flexible connectivity to PLC or SCADA systems.


Intuitive Interface

User-friendly soft-key operation for quick menu navigation, parameter setting, and real-time monitoring.


Dual Alarm Control

Integrated high and low limit relay contact points (3A/AC250V) for immediate system safety response.

Product Gallery

Management Platforms

Remote Monitoring

Utilize Modbus RS485 for centralized data collection and real-time pH tracking across multiple sites.

Automated Control

Connect 4-20mA output to dosing pumps for automated pH neutralization and adjustment.

Alert Management

Configurable High/Low limit relay outputs provide instant alerts to prevent water quality violations.

Calibration Tracking

Systematic three-point calibration logs ensure the instrument remains within precise accuracy limits.

System Integration

Standard DIN rail installation allows for high-density mounting in industrial control panels.

Sensor Maintenance

Easily replaceable compound electrodes with 3/4" NPT joints for minimal downtime during service.

Investment Return Comparison

MetricStandard MeterPH-TRA-600
Installation CostHigh (Custom)Low (DIN Standard)
Calibration TimeManual / SlowAuto / Rapid
Integration EffortAnalog OnlyDigital (RS485/4-20mA)
Maintenance CycleFrequentExtended (Industrial Grade)
Operational RiskHigh (Manual Check)Low (Automatic Alarm)

Frequently Asked Questions

Q: How often should the PH-TRA-600 be calibrated for water pollution monitoring?

Depending on the water contamination level, we recommend a three-point calibration every 1-4 weeks to maintain the ±0.1pH accuracy required for environmental compliance.

Q: Can this transmitter be used in high-pressure water pipelines?

Yes, the electrodes feature a compression resistance of 0 to 0.5MPa, making them suitable for most standard industrial water pipelines.

Q: What is the difference between the RS485 and 4-20mA outputs?

The 4-20mA output provides a linear analog signal for simple controllers, while Modbus RS485 allows for digital communication of multiple parameters over longer distances.

Q: How do I handle electrode fouling in industrial wastewater?

We recommend regular cleaning using surface active agents for grease, or 10% hydrochloric acid for calcium and sulphide precipitates.

Q: Is temperature compensation necessary for pH measurement?

Absolutely. pH values vary with temperature. The PH-TRA-600 supports manual and automatic compensation (PT1000/NTC10K) to ensure readings remain accurate from 0 to 120℃.

Q: What should I do if the instrument displays "ERR" during calibration?

An "ERR" signal indicates calibration failure. Please re-calibrate. If the error persists, it may indicate a damaged electrode that needs replacement.

Looking for a Reliable pH Monitoring Solution for Your Plant?

Contact Us

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

                  
       
                

Related Products

right
right
RO Membrane

RO Membrane

PH-6800

PH-6800

WS-9200/9250

WS-9200/9250

RO-8100

RO-8100

RO- 8200

RO- 8200

ORP-6800

ORP-6800

PH/ORP-600

PH/ORP-600

JIRS-803C

JIRS-803C

Related News

right
right
Rotameter FAQ for small-flow measurement in water treatment

Nov.03,2026

Rotameter FAQ for small-flow measurement in water treatment

Learn how a Rotameter measures fluid flow, where it fits in water-treatment and RO systems, and which accuracy, pressure, and float details to review before ordering.

Choosing WS 9100: Application Fit and Specification Checks

Oct.29,2026

Choosing WS 9100: Application Fit and Specification Checks

Evaluate whether the WS 9100 fits your environmental monitoring project. Review power supply options, temperature-controlled storage, sampling method compatibility, and key specifications before purchasing.

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

Oct.23,2026

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

PH/ORP-6850 FAQ: pH 0–14 and ORP ±1200 mV ranges, ±0.02 pH accuracy, isolated 4–20 mA output, relay alarms, power supply options and panel installation.

Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish