ROS2210 RO System Controller Professional Water Quality Monitoring China Factory Suppliers

The ROS-2210 combines reverse osmosis control and dual conductivity measurement. As leading China factory suppliers, we provide this professional tool to clearly view inlet and produced water data and RO equipment status for optimal industrial water treatment.

Product Details

Product Details

Contact Now

Contact Now

Product Details

The ROS-2210 is a professional-grade Reverse Osmosis (RO) system controller engineered for precision water quality monitoring. Designed for versatility, this instrument supports two critical operation modes: Source Tank Supply and Tap Water Supply, making it an ideal solution for diverse industrial and laboratory water treatment environments.

Equipped with high-performance conductivity sensors and an intuitive LCD interface, the ROS-2210 ensures optimal RO system performance by providing real-time monitoring of both source and production water. Its robust design and automatic temperature compensation guarantee accuracy and reliability in demanding water pollution prevention and control applications.

Detailed Parameters

Measuring Range0 ~ 2000us / cm (Source & Production)Accuracy1.5% FS
Matched ElectrodeABS1.0 Platinum Black ElectrodeCable Length4.5 Meters (2pcs included)
Power SupplyAC220V ±15% 50HZ / Optional DC24VPower Consumption≤10W
Operating Temp5~60°CHumidity Range≤85%RH
Output Capacity3A/250V AC (Relay driven)Dimensions9696130 mm (LWD)

Key Advantages


Dual-Mode Operation

Seamlessly switches between Source Tank and Tap Water supply modes to adapt to any facility layout.


Auto-Compensation

Integrated automatic temperature compensation based on 25°C for consistent, drift-free readings.


Industrial Precision

Utilizes platinum black electrodes to ensure high sensitivity and long-term stability in conductivity measurement.


Full-View LCD

High-contrast liquid crystal display provides clear, real-time visibility of critical water parameters.


Flexible Installation

Standard 9292mm dial opening allows for easy integration into existing control panels.


Load Protection

Optimized relay design supports intermediate relay integration to protect the controller from inductive loads.

Product Gallery

Management Platforms

Full Kit Integration

Includes ROS-2210 controller, dual sensors, manual, and certification for immediate deployment.

Precision Calibration

Easy calibration process to maintain the 1.5% FS accuracy across all measuring ranges.

Valve Automation

Direct control of solenoid valves and pumps via integrated relay outputs.

System Monitoring

Continuous real-time tracking of source vs production water conductivity levels.

Modular Hardware

Standardized dimensions and mounting clamps for flexible industrial cabinet installation.

Thermal Management

Stable performance in temperatures from 5°C to 60°C, ensuring operational uptime.

Investment Return Comparison

MetricTraditional MonitoringROS-2210 System
Installation CostHigh (Complex Setup)Low (Integrated Kit)
Calibration TimeManual & SlowRapid & Precise
Energy EfficiencyStandard ConsumptionUltra-Low (≤10W)
Component LifespanFrequent Relay WearExtended (Relay Protected)
Accuracy StabilityTemperature DependentAuto-Compensated

Frequently Asked Questions

Q: How does the ROS-2210 handle temperature fluctuations in water quality measurement?

The ROS-2210 features an automatic temperature compensation system based on a 25°C reference, ensuring that conductivity readings remain accurate regardless of medium temperature changes between 5°C and 60°C.

Q: What is the best way to connect the controller to high-power pumps?

Since the controller uses small relays to save space, we strongly recommend using an intermediate relay or base paint when driving large inductive loads to extend the service life of the device and reduce failure rates.

Q: Can the ROS-2210 be used for both raw water and purified water monitoring?

Yes, it is specifically designed for this. It supports dual measuring ranges (0 ~ 2000us/cm) for both source water and production water, typically using two matched ABS1.0 platinum black electrodes.

Q: What power options are available for industrial integration?

The standard power supply is AC220V ±15% 50HZ. However, for industrial PLC environments or DC-powered systems, an optional DC24V power supply is available.

Q: How does the ROS-2210 contribute to water pollution prevention?

By providing precise conductivity and TDS monitoring, it allows operators to detect membrane breakthrough or contamination instantly, ensuring that discharged water meets environmental standards.

Q: What is the maximum distance for sensor installation?

The system supports a measuring distance of up to 30 meters, providing significant flexibility for piping layouts in large industrial water treatment plants.

Ready to Optimize Your Water Monitoring System?

Contact Us

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

                  
       
                

Related Products

right
right
RO Membrane

RO Membrane

PH-6800

PH-6800

WS-9200/9250

WS-9200/9250

RO-8100

RO-8100

RO- 8200

RO- 8200

ORP-6800

ORP-6800

PH/ORP-600

PH/ORP-600

JIRS-803C

JIRS-803C

Related News

right
right
Rotameter FAQ for small-flow measurement in water treatment

Nov.03,2026

Rotameter FAQ for small-flow measurement in water treatment

Learn how a Rotameter measures fluid flow, where it fits in water-treatment and RO systems, and which accuracy, pressure, and float details to review before ordering.

Choosing WS 9100: Application Fit and Specification Checks

Oct.29,2026

Choosing WS 9100: Application Fit and Specification Checks

Evaluate whether the WS 9100 fits your environmental monitoring project. Review power supply options, temperature-controlled storage, sampling method compatibility, and key specifications before purchasing.

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

Oct.23,2026

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

PH/ORP-6850 FAQ: pH 0–14 and ORP ±1200 mV ranges, ±0.02 pH accuracy, isolated 4–20 mA output, relay alarms, power supply options and panel installation.

Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish