YD6850 Online Salinity Controller Factory Suppliers in China

Buy high-precision YD-6850 online salinity controllers from leading China factory suppliers. Featuring a large LCD screen, automatic temperature compensation 0-100C, 4-20mA output, and RS-485 MODBUS communication for industrial water quality monitoring.

Product Details

Product Details

Contact Now

Contact Now

Product Details

The YD-6850 Online Salinity Transmitting Controller is a professional-grade analytical instrument designed for the continuous monitoring of salinity values in challenging industrial environments. Engineered for high precision and stability, it serves as a critical tool for water quality management, ensuring that solution salinity remains within optimal operational limits across diverse industrial sectors.

Specifically developed for versatility, the YD-6850 is widely deployed in thermal power plants, chemical fertilizer production, metallurgy, pharmaceutical synthesis, and biochemical laboratories. Its robust design and integrated temperature compensation make it an indispensable asset for environmental protection agencies and food processing facilities requiring rigorous water pollution prevention and monitoring.

Detailed Parameters

Measuring Range0-300‰ Resolution0.1‰
Accuracy±2.0 %(FS) DisplayLarge screen LCD
Sensor Material3/4” NPT PSF (Polysulfone) Cable Length5m cable
Temp. CompensationNTC 10K (0.0℃-100.0℃) Current Output4 ~ 20 mA (Photoelectric isolation)
Control OutputTwo groups of ON/OFF relay contacts Power SupplyAC 220V±10%, 50/60Hz

Key Advantages

Industrial Durability

Featuring an IP65 protection grade and PSF sensor material for superior corrosion resistance in harsh environments.

Real-time Monitoring

Provides continuous salinity tracking with a high-resolution LCD for immediate data visualization and analysis.

High Precision

Achieves an accuracy of ±2.0% FS, ensuring reliable data for critical biochemical and metallurgical processes.

Smart Compensation

Integrated NTC 10K automatic temperature compensation eliminates thermal drift for stable readings up to 100℃.

Isolated Signal Output

Equipped with photoelectric coupler isolation to prevent interference and ensure signal purity for 4-20mA output.

Easy Integration

Standard panel mount design (92x92mm hole) allows for seamless installation into existing control cabinets.

Product Gallery

Management Platforms

Salinity Control

Precise adjustment of salinity levels via the integrated relay control system.

PLC Integration

Standard 4-20mA output enables effortless connection to industrial PLC systems.

Alarm Notification

Dual ON/OFF relay contacts for immediate alerting during threshold violations.

Thermal Monitoring

Integrated temperature signal output for synchronized thermal and salinity tracking.

Remote Data Logging

Supports external data acquisition for long-term water quality trend analysis.

System Calibration

User-friendly interface for rapid calibration to maintain peak measurement accuracy.

Investment Return Comparison

Comparison MetricConventional Manual TestingYD-6850 Online System
Labor CostHigh (Daily Sampling)Ultra-Low (Automated)
Data AccuracySubject to Human ErrorHigh Precision Digital
Response TimeDelayed (Lab Result)Instantaneous (Real-time)
MaintenanceFrequent ConsumablesLow-Maintenance PSF Sensor
Risk MitigationReactive CorrectionProactive Prevention

Frequently Asked Questions

Q: What industries are most suitable for the YD-6850 salinity controller?

It is ideal for thermal power plants, chemical fertilizer production, metallurgy, pharmaceutical, biochemical, and food industries, as well as general environmental water protection monitoring.

Q: How does the YD-6850 handle temperature fluctuations?

The device features an NTC 10K automatic temperature compensation system covering 0.0℃ to 100.0℃, ensuring that salinity readings remain accurate regardless of fluid temperature changes.

Q: Is the sensor material resistant to corrosion?

Yes, the sensor is constructed from PSF (Polysulfone) material, which provides excellent chemical resistance and durability in corrosive water environments.

Q: What outputs are available for system integration?

The YD-6850 provides a 4-20mA current output with photoelectric isolation for analog signals and two groups of ON/OFF relay contacts for digital control and alarms.

Q: What is the installation method for this controller?

It is a panel-mounted device requiring a hole size of 92×92mm. It is designed for easy integration into industrial control panels.

Q: Does the device meet industrial protection standards?

Yes, the YD-6850 is rated IP65, meaning it is dust-tight and protected against water jets, making it suitable for industrial site installations.

Ready to Optimize Your Water Quality Monitoring?

Contact Us

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

What's the MOQ?

Down Down

1set sample is available.

What's your price?

Down Down

We quoted based on your products’ code and qty. We can offer different discount depending on qty.

I am not sure of the required product type, how to get quotation?

Down Down

Please tell us the details of your project: Measuring range, temperature, pressure, If need relay control output, 4-20mA or Modbus RS485 output? We will choose suitable product type as per your project details and make quotation for you.

How long is your delivery time?

Down Down

Most of our products are in stock. Generally, we can delivery to you within 2-3 working days. The big order’s delivery time will be determined according to the type and quantity of products ordered.

What’s your term of payment?

Down Down

We accept T/T, Paypal, Western Union, Alipay, credit card, wechat and other suitable payment.
                  
       
                

Related Products

right
right
RO Membrane

RO Membrane

PH-6800

PH-6800

WS-9200/9250

WS-9200/9250

RO-8100

RO-8100

RO- 8200

RO- 8200

ORP-6800

ORP-6800

PH/ORP-600

PH/ORP-600

JIRS-803C

JIRS-803C

Related News

right
right
Rotameter FAQ for small-flow measurement in water treatment

Nov.03,2026

Rotameter FAQ for small-flow measurement in water treatment

Learn how a Rotameter measures fluid flow, where it fits in water-treatment and RO systems, and which accuracy, pressure, and float details to review before ordering.

Choosing WS 9100: Application Fit and Specification Checks

Oct.29,2026

Choosing WS 9100: Application Fit and Specification Checks

Evaluate whether the WS 9100 fits your environmental monitoring project. Review power supply options, temperature-controlled storage, sampling method compatibility, and key specifications before purchasing.

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

Oct.23,2026

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

PH/ORP-6850 FAQ: pH 0–14 and ORP ±1200 mV ranges, ±0.02 pH accuracy, isolated 4–20 mA output, relay alarms, power supply options and panel installation.

Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.