The WS 9100 is a portable automatic water sampler designed for environmental monitoring applications. This guide walks procurement teams through the key selection criteria — power supply flexibility, temperature-controlled sample storage, sampling method compatibility, and programmability — so buyers can assess whether the WS 9100 fits their site conditions and project requirements before purchasing.

Power supply compatibility: the WS 9100 supports 12 V DC input via mains adapter, standalone battery, or battery-plus-solar — buyers must confirm which source matches the deployment site.
Sample temperature management: the integrated refrigeration/heating chamber maintains sample integrity from −25 °C to +50 °C, eliminating ice dependency; buyers should verify this range meets their regulatory preservation requirements.
Sampling method and reach: supports time-based composite and flow-proportional modes with 50–7,500 ml volume range, 8 m vertical and 50 m horizontal suction head — buyers must confirm the intake geometry and monitoring protocol match these parameters.
Storage volume and programme count: single 7,500 ml polyethylene bottle standard; up to 10 programmes storable — buyers should confirm these limits suit their unattended sampling intervals and scheduling needs.
The WS 9100 is a MODEL 9100 Series Portable Automatic Water Sampler from Hebei JIRS Import & Export Co., Ltd., engineered for environmental monitoring fieldwork. It combines a peristaltic pump draw system, a temperature-controlled storage chamber, and a fully programmable microchip controller to collect discrete or composite water samples at remote or on-site locations.
Before specifying the WS 9100 for a project, procurement teams should confirm that the unit's power options, storage conditions, sampling range, and operational limits match the actual deployment environment.
The WS 9100 operates on 12 V DC at 80 W. Three power source configurations are supported:
Selection check: Confirm whether the target site has mains power, battery logistics, or sufficient solar exposure. The three-way power flexibility is a primary reason the WS 9100 is used in remote environmental monitoring programmes.
The WS 9100 incorporates a temperature-controlled sample storage chamber that supports both refrigeration and heating. This eliminates the need for ice packs and allows uninterrupted monitoring when outdoor temperatures drop below freezing. The stated working temperature range is −25 °C to +50 °C.
Selection check: If the sampling programme requires preservation of sample integrity across wide seasonal or daily temperature swings — particularly in cold-climate or desert environments — the integrated thermal management chamber is a relevant differentiator. Buyers who only operate in mild climates should still confirm that the chamber meets their regulatory sample-preservation specifications.
The WS 9100 supports two primary sampling approaches:
| Sampling Mode | Key Parameter Range |
|---|---|
| Composite / Time-based | Delay: 1–9,999 min; Interval: 1–9,999 min; Volume: 50–7,500 ml (1 ml increments); Mixed samples: 1–200 |
| Flowmeter-controlled | Dedicated flowmeter input; pulse-output flow sensor support; 1–9,999 pulses per trigger |
The peristaltic pump delivers 3.7 L/min, with a vertical suction head of 8 m and a horizontal suction distance of 50 m. The sampling tube has an automatic air purge function.
Declared accuracy figures: sampling error ±5% and repeat sampling accuracy ±5 ml.
Selection check: Match the required sampling mode (time-proportional composite vs. flow-proportional composite) to the monitoring permit or project protocol. Verify that the 8 m vertical and 50 m horizontal reach are sufficient for the intake point geometry at the target site.
The standard configuration includes one 7,500 ml polyethylene bottle. Buyers whose programme requires larger aggregate sample volumes or multi-bottle distribution should clarify this with Hebei JIRS Import & Export Co., Ltd. before ordering, as the single-bottle configuration is the published standard.
Selection check: Confirm that a single 7,500 ml container is adequate for the longest unattended sampling interval in the programme. If composite volumes per collection cycle exceed this, a different configuration or more frequent collection is needed.
The WS 9100 is controlled by a single-microchip computer with the following programmable features:
Selection check: For unattended or multi-shift deployments, confirm that the required number of sampling schedules fits within the 10-programme limit. The power-off data retention feature is important for sites with unreliable grid power.
The published dimensions are 580 mm (L) × 320 mm (W) × 520 mm (H) with a weight of 15 kg. Pipeline air tightness is rated at ≤ −0.05 MPa, and insulation resistance is > 20 MΩ.
Installation precautions from the product documentation include:
Selection check: Verify that the 15 kg unit weight and enclosure dimensions are compatible with transport logistics, shelter or housing requirements, and any local installation standards at the monitoring station.
| Parameter | Value |
|---|---|
| Power supply | 12 V DC, 80 W |
| Working temperature | −25 °C to +50 °C |
| Peristaltic pump flow rate | 3.7 L/min |
| Vertical suction head | 8 m |
| Horizontal suction head | 50 m |
| Sampling volume range | 50–7,500 ml (1 ml increments) |
| Sampling error | ±5% |
| Repeat sampling accuracy | ±5 ml |
| Sampling bottle | 1 × 7,500 ml polyethylene |
| Programmes storable | 10 |
| MTBF | ≥ 1,440 h/time |
| Insulation resistance | > 20 MΩ |
| Pipeline air tightness | ≤ −0.05 MPa |
| Dimensions (L × W × H) | 580 × 320 × 520 mm |
| Weight | 15 kg |
The WS 9100 is well-suited to buyers who need:
The WS 9100 from Hebei JIRS Import & Export Co., Ltd. is a flexible portable automatic water sampler built for environmental monitoring across a broad range of site conditions. Procurement teams should verify power source availability, sample preservation temperature requirements, intake geometry (vertical and horizontal suction head), and programme count against their project protocols. Use the specification table above as a pre-order checklist to confirm application fit before finalising a purchase decision.
THE PEOPLE

About the author
Watequipments Team
THE COMPANY
Hebei JIRS Import & Export Co., Ltd., we specialize in providing top-notch water quality analysers and sensors that meet the diverse needs of our clients. Our products include: Conductivity/TDS controllers, Resistivity controllers, pH/ORP controllers, Reverse Osmosis (RO) controllers, Dissolved Oxygen Controllers, Residual Chlorine Controllers, Turbidity Controllers, Salinity Controllers, Irrigation system controller and a variety of related sensors.…
About Us ↗Visit company website ↗YOUR NEXT STEP
Use case, specification, quantity and delivery window: make the next conversation specific.
Related Products
Related News


2026-11-03 04:36:32
Rotameter FAQ for small-flow measurement in water treatmentLearn how a Rotameter measures fluid flow, where it fits in water-treatment and RO systems, and which accuracy, pressure, and float details to review before ordering.
2026-10-23 04:19:53
PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering QuestionsPH/ORP-6850 FAQ: pH 0–14 and ORP ±1200 mV ranges, ±0.02 pH accuracy, isolated 4–20 mA output, relay alarms, power supply options and panel installation.
2026-07-01 09:39:59
Guide to Ensuring Water Purity for drinking water tds MonitoringEnsuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.
2026-06-29 16:58:21
Understanding the Conversion of Electrical Conductivity to TDSUnderstanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.
2026-06-27 17:38:40
Industrial Guide to Electrical Conductivity Salt Water MonitoringUnderstanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.
2026-06-26 16:42:22
Technical Guide to Industrial ec meter circuit Design and UseUnderstanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.
2026-06-25 18:39:20
Professional Guide to drinking water testing for tds and PurityDrinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.
If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.