Introduction:
FL-8860 is a wall-mounted transit-time ultrasonic flow meter designed for non-invasive liquid flow measurement. Equipped with external clamp-on transducers, it mounts fully outside pipelines without cutting pipes, stopping production or contacting measured media, eliminating leakage and medium contamination risks.
Adopting advanced multi-pulse low voltage ultrasonic technology, it delivers superior accuracy of ±1%, repeatability up to 0.2%, and stable measurement for various homogeneous liquids. Compatible with pipe diameters from DN15 to DN6000 and multiple pipe materials including steel, stainless steel, PVC, cast iron and FRP.
This all-in-one flow controller integrates real-time instantaneous flow, cumulative totalizer, heat energy calculation, multi-channel alarm, batch dosing control and built-in 5-year data storage. Rich industrial communication & analog outputs support seamless connection with PLC, DCS and SCADA systems, widely deployed in water treatment, chemical, oil, HVAC and food processing industries.
Main Characteristics:
High Accuracy:Better than ±1%
Wide Measuring Range:Several types transducer for selection, pipe size from Dn15mm to Dn6000mm
High Reliability:Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability.
Strong Anti-interference:Dual-balance signal differential receiver/driver circuit to avoid interference of converter, TV , tower, high voltage line etc.
Powerful Recording Function(Automatically record the following data):
The totalizer data of the last 512 days/128 months/10 years
The time and corresponding flow rate of the last 64 times of power on and off events
The working status of the last 32 days
Far transmission distance, easy for networking
RS485 support wireless network, connect GPRS module to accomplish wireless transmission .
Support Heat Measurement
Connect the temperature transducer , can finish the heat/ energy measurement
Main Technical Index:
| Item | Specification |
|---|
| Model | FL-8860 Wall Mount Ultrasonic Flow Meter |
| Measuring Principle | Transit Time Difference Method |
| Accuracy | ≤±1% FS |
| Repeatability | ≤0.2% |
| Measuring Period | 500ms |
| Pipe Size Range | DN15 ~ DN6000mm |
| Supported Pipe Materials | Carbon steel, stainless steel, cast iron, PVC, aluminum, FRP, lined pipes |
| Liquid Temperature | Standard: -30~90℃; High Temp: -30~160℃ |
| Allowable Liquid Turbidity | ≤10000ppm, tiny bubbles acceptable |
| Installation Modes | V / Z / W / N 4 optional transducer layouts |
| Signal Output | 4-20mA analog, OCT frequency pulse, relay alarm, RS485 MODBUS |
| Optional Input | 3-channel PT100 temperature sensor (heat metering) |
| Data Storage | 64 days / 64 months / 5 years flow & energy records |
| Power Supply | AC220V or DC24V |
| Power Consumption | <1.5W |
| Communication Distance | Max 1000m via twisted pair cable |
| Working Humidity | Main unit ≤85%RH; Transducer submersible within 3m water |