Answers to buyer questions about the PH/ORP-6850 single-channel industrial online pH/ORP controller from Hebei JIRS Import & Export Co., Ltd.: measuring ranges, accuracy, outputs, power supply choices, optional features, panel installation and probe mounting. Pricing, lead time and warranty terms are not covered by the published product information and should be confirmed directly.

The PH/ORP-6850 is an industrial online controller from Hebei JIRS Import & Export Co., Ltd. It measures and controls the pH or ORP of water continuously. This FAQ covers the questions buyers, distributors and procurement teams usually need answered before they ask for a quote: what the controller measures, its published technical index, which options can be chosen at order, and how it is installed. Every answer comes from the published product information.
This is a single-channel instrument. It measures pH or ORP and controls that value continuously. According to the product information, applications include municipal wastewater treatment, chemistry, printing and dyeing, paper, medicine, plating and environmental production.
| Item | Published value |
|---|---|
| Measuring range | pH 0–14 pH; ORP −1200 to +1200 mV |
| Accuracy | ±0.02 pH; ±1 mV |
| Resolution | 0.01 pH; 1 mV (0.1 mV optional) |
| Stability | ≤0.02 pH/24 h; ≤3 mV/24 h |
| pH standard solutions | 4.00/6.86/9.18 (standard); 4.01/7.00/10.01 (optional) |
| Display | 128 × 64 dot matrix LCD, English language display |
| Temperature compensation | 0–120 ℃, manual/automatic, PT1000 RTD |
| Signal output | One isolated 4–20 mA output, max loop resistance 750 Ω |
| Alarm output | High and low limit alarm contacts (3A/250V AC), normally open relays |
| Power supply | AC220V ±10%, 50/60 Hz; AC110V ±10%, 50/60 Hz; DC24V, 0.5 A |
| Power consumption | ≤3 W |
| Working environment | 0–60 ℃; humidity ≤95% RH |
| Outline dimension | 96 × 96 × 127 mm (height × width × depth) |
| Panel cut-out | 93 × 93 mm (height × width) |
The unit offers high/low limit control with a double relay, a pH high/low limit alarm light and a settable alarm delay. The current output is isolated. Digital communication output is listed as optional, and the rear terminal chart includes RS485 A+ and B− terminals. PID control through the 4–20 mA output, used to drive a powered actuator, is also listed as optional.
Other published characteristics:
The controller is panel mounted. Insert it from the front panel into the 93 × 93 mm cut-out, fit the clamps on the left and right, and tighten them. When mounting the probe on a pipe, avoid air bubbles at the probe, because they make the readings inaccurate. The product documentation includes installation charts for this.
The published information does not cover pricing, minimum order quantity, lead time, warranty, certifications, or which probe is included as standard. Confirm these directly with Hebei JIRS Import & Export Co., Ltd. when requesting a PH/ORP-6850 quotation, along with the power supply version and optional functions you need.
The detailed questions and answers below cover specifications and configuration choices.
THE PEOPLE

About the author
Watequipments Team
THE COMPANY
Hebei JIRS Import & Export Co., Ltd., we specialize in providing top-notch water quality analysers and sensors that meet the diverse needs of our clients. Our products include: Conductivity/TDS controllers, Resistivity controllers, pH/ORP controllers, Reverse Osmosis (RO) controllers, Dissolved Oxygen Controllers, Residual Chlorine Controllers, Turbidity Controllers, Salinity Controllers, Irrigation system controller and a variety of related sensors.…
About Us ↗Visit company website ↗YOUR NEXT STEP
Use case, specification, quantity and delivery window: make the next conversation specific.
Related Products
Related News


2026-11-03 04:36:32
Rotameter FAQ for small-flow measurement in water treatmentLearn how a Rotameter measures fluid flow, where it fits in water-treatment and RO systems, and which accuracy, pressure, and float details to review before ordering.
2026-10-29 03:32:11
Choosing WS 9100: Application Fit and Specification ChecksEvaluate whether the WS 9100 fits your environmental monitoring project. Review power supply options, temperature-controlled storage, sampling method compatibility, and key specifications before purchasing.
2026-07-01 09:39:59
Guide to Ensuring Water Purity for drinking water tds MonitoringEnsuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.
2026-06-29 16:58:21
Understanding the Conversion of Electrical Conductivity to TDSUnderstanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.
2026-06-27 17:38:40
Industrial Guide to Electrical Conductivity Salt Water MonitoringUnderstanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.
2026-06-26 16:42:22
Technical Guide to Industrial ec meter circuit Design and UseUnderstanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.
2026-06-25 18:39:20
Professional Guide to drinking water testing for tds and PurityDrinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.
If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.