WS-9200 (portable separate sampling) automatic water sampler is a special environmental monitoring instrument for surface water and sewage sampling, water source monitoring, pollution source investigation and total amount control. It uses the international common peristaltic pump water intake mode, controlled by the single-chip microcomputer. Users can input sampling time interval, sampling amount and sampling mode according to their needs. It can automatically complete the corresponding work online. When connected with flow sensor, it can realize double work of sewage metering and sampling according to flow ratio. This instrument is a portable bottle water sampler, equipped with DC 12V-16.8V (standard external large capacity lithium battery 14.8V 7.8AH) power supply, suitable for all levels of environmental monitoring stations, labor hygiene, scientific research institutes to rivers, lakes, sea surface water or pollution sources after determining the sampling point automatically used.

Product Details

Product Details

Contact Now

Contact Now

Product Details


Ordering Information

Model: WS-9200

Specification: 1000ml×24 bottles of multifunctional equal proportion

For purchase or quotation please contact product manager

Product Introduction

Application Industry

Used in all kinds of water environment scientific research and environmental monitoring stations, water conservancy hydrology, health and epidemic prevention stations, disease control centers, universities, environmental impact assessment departments and other daily work all need portable water environment.

Product Features

 

  • •24* 1000ml sampling bottles;
  • • Distribution system self-lubricating, positioning self-locking type;
  • • Color LCD screen, simple and clear operation;
  • • Sampling peristaltic pump diameter large, fast flow rate, can effectively avoid pipeline blockage;
  • • Configuration Configuration DC 12V-16.8V (standard external large capacity lithium battery 14.8V 7.8AH) power supply;
  • • ABS shell protection class IP65, can be used in the field all-weather, easy to carry;
  • • Independent R & D, modular design, high integration, low failure rate, simple and convenient maintenance;
  • • Optional intelligent cloud management platform.
WS-9200
 

 

 

Technical Indicators

project

Indicators

Sampling mode

Standard sampling:

Sampling delay time: ( 1~9999 minutes) arbitrarily set, increment 1 minute

Sampling interval time: ( 1~9999 minutes) Set arbitrarily, increment 1 minute

Sampling volume: (5~1000 mL) Set arbitrarily, increment 1 ml

Mixed sampling:

Sampling delay time: ( 1~9999 minutes) arbitrarily set, increment 1 minute

Sampling interval time: ( 1~9999 minutes) Set arbitrarily, increment 1 minute

Sampling volume: (5~1000 mL) Set arbitrarily, increment 1 ml

Number of mixed samples: ( 1~20)

Parallel sampling:

Sampling delay time: ( 1~9999 minutes) arbitrarily set, increment 1 minute

Sampling interval time: ( 1~9999 minutes) Set arbitrarily, increment 1 minute

Sampling volume: (5~1000 mL) Set arbitrarily, increment 1 ml

Number of parallel samples: ( 1~24)

Flow Trigger:

Flow Trigger Sampling: Dedicated flow meter control sampling. Ultrasonic liquid  level sensor is required, 1~9999 cubic meters of water can be set arbitrarily, and the increment is 1 cubic meter.

Pulse trigger:

Sampling 1~ 9999 pulses arbitrarily set, increment 1 pulse. Pulse received is passive pulse with closing time greater than 1 second

* Sampling

pump

characteristics

Sampling flow rate:3700 mL/min

Pump tube inner diameter: 10 mm

Pump tube material: high strength medical silicone tube

Pump assembly material:

The pump body is reinforced engineering plastic, quick disassembly module combination, motor shaft, pump tube roller bracket is stainless steel material

Sampling error: ±5%

Sampling repeatability: ±5mL Vertical lift: 8 m

Horizontal suction range: 50 m

Air tightness of pipeline system: ≤-0.085MPa

Software function

 

Operation interface:

large screen 2.8 TFT color LCD screen, all Chinese menus, man-machine dialogue mode, Chinese prompt when manual intervention is required

Bottle sampling:

* The instrument can realize 1-24 bottle sampling, the number of bottles can be freely set, the distribution system is self-lubricating, positioning self-locking type, using direct water   injection, avoiding cross contamination of water samples caused by guide plate.

Rinse the pipeline:

Rinse the pipeline in a "blow-suction-blow" manner to avoid cross-contamination of samples Software code lock: can protect the instrument set program is not modified

Sampling program preset:

10 commonly  used  working  programs  can  be  preset  and  stored  according  to  sampling requirements, and can be directly called later.

External pump control:

Sampling  distance  can  be  extended  by  controlling  external  submersible  or  self-priming pumps

Sampling records:

Sampling time, sampling status, sampling bottle No. It can store 5000 items.

Flow records:

Time,  instantaneous  flow,  cumulative  flow.  6000  pieces  can  be  stored  (ultrasonic  level sensor is required)

Other

parameters

Water storage containers:

24 1000ml polyethylene water storage bottles

Pre-filter:

Special filter head. Stainless steel filters of corresponding mesh can be selected according to water quality

System clock time control error: △1≤0.05% and △12≤3S

MTBF:≥1440h/time

Insulation impedance:>20MΩ Communication interface:

Internal MODBUS protocol

1 RS232/RS485 digital interface (default RS232)  Analog input 1 channel 4~20mA, 12-bit resolution Switching input 1 passive

Switching output 1 active, 15VDC/200mA

Conditions of use

Power supply:

DC 12V-16.8V (standard external large capacity lithium battery 14.8V 7.8AH) Rated power: 35W

Operating environment temperature: -5℃ to +50℃ Working environment humidity: 5-85%RH

Shell material:

ABS material, light, acid and alkali resistance, corrosion resistance, aging resistance

Protection class: IP65 Weight: 15kg

Appearance size:480mm×720mm (diameter × height)

* Optional

1. Optional intelligent cloud management platform to realize remote cloud platform control. (Sampling can be remotely set by any Internet computer or mobile phone)

2. Ultrasonic liquid level sensor (realize flowmeter function)

 

WS-9200WS-9200WS-9200

 

 

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

Frequently Asked Questions (FAQ) About WS 9200

What is the WS 9200 sampler used for?

Down Down

Automatically collect water samples for detection and analysis.

How do I install the WS 9200 sampler?

Down Down

Install in appropriate location according to instructions.

How to operate the WS 9200 sampler?

Down Down

Start automatic sampling after setting parameters.

What is the problem with the WS 9200 sampler?

Down Down

Pump failure or pipeline blockage, etc.
WS-9200-1.webp                  
       
                

Related Products

right
right
RO Membrane

RO Membrane

PH-6800

PH-6800

WS-9200/9250

WS-9200/9250

RO-8100

RO-8100

RO- 8200

RO- 8200

ORP-6800

ORP-6800

PH/ORP-600

PH/ORP-600

JIRS-803C

JIRS-803C

Related News

right
right
Rotameter FAQ for small-flow measurement in water treatment

Nov.03,2026

Rotameter FAQ for small-flow measurement in water treatment

Learn how a Rotameter measures fluid flow, where it fits in water-treatment and RO systems, and which accuracy, pressure, and float details to review before ordering.

Choosing WS 9100: Application Fit and Specification Checks

Oct.29,2026

Choosing WS 9100: Application Fit and Specification Checks

Evaluate whether the WS 9100 fits your environmental monitoring project. Review power supply options, temperature-controlled storage, sampling method compatibility, and key specifications before purchasing.

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

Oct.23,2026

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

PH/ORP-6850 FAQ: pH 0–14 and ORP ±1200 mV ranges, ±0.02 pH accuracy, isolated 4–20 mA output, relay alarms, power supply options and panel installation.

Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish