PH/ORP-6800

PH/ORP-6800 is a single-channel industrial panel monitor for real-time PH & ORP measurement and automatic control. It covers pH 0~14 and ORP -1200~+1200mV with high precision, supporting auto/manual temperature compensation. Equipped with dual limit relays, isolated 4-20mA output and optional Modbus RS485, it features bilingual LCD, password lock and adjustable backlight. Multiple global power options are available. Widely used in wastewater, plating, chemical, printing & dyeing and pharmaceutical water treatment. Factory pre-calibrated probes for direct installation.

Product Details

Product Details

Contact Now

Contact Now

Product Details

Introduction:

Industrial online PH/ORP controller PH/ORP-6800 is single channel PH or ORP controller. It can measure and control PH and ORP value of water continuously, the PH/ORP controller is applicable for municipal waste water treatment, chemistry, printing and dyeing, paper, medicine, plating and environmental production etc.

In accordance with the environment and characteristics of water industry, as well as the international power supply standard, considering the electricity design in special environment, the PH/ORP controller could be supplied with power 220V AC, 110V AC and safe low voltage 24V AC, 24V DC for selection.

Main Characteristics:

English language display

Measure pH or ORP, high/low limit control, current output, digital communicationoutput (Optional)

It could be set automatic/manual temperature compensation

pH high/lowlimit alarm light, double relay, alarm delay could be set

Instrument mode isolated transmitting port, max circle resistance up to 750Ω

Backlight of LCD could select power saving mode, timing automatic off, brightness adjust,

High performance CPU, good electromagnetic compatibility

AC input be fuse

ESDover voltage protection is available

Password management avoid non-professional person to operate

 Main Technical Index

PH/ORP-6800

Outline dimensions and fixed Installation

 Insert the controller from the front panel, install the fix clamp(up and down), tighten with the screws.

PH/ORP-6800

Chart 1  Fixed support installation  

Probe Installation

Installation method and Attention-matter

PH/ORP-6800

                                                           Chart 2(Several common method of installation)

In order to make sure the probe measure the real value on the pipe, bubbles should be avoided ,otherwise the value will be not accurate, please install according to the following chart: 

PH/ORP-6800

                                 Chart 3(attention matters of pipe installation)

Relay alarm description:

When the relay is higher than (or lower than) the alarm pull in value acts, and when it is lower than (or higher than) the open limit value releases, the relay action diagram is as follows

PH/ORP-6800

Note: When the relay drives the inductive load, please install an intermediate relay to prevent the contact from being broken down and ionized by the inductive back EMF and burning the contact.

4-20mA current output formula

1.PH Current output formula:
Factory setting define output current value is :0 pH is corresponding value of 4 mA; 14 pH is corresponding value of 20 mA.
I = ( D - 4 mA corresponding value)× ( 16 / (20 mA corresponding value- 4 mA corresponding value) ) + 4.00
I = ( D - 0 )× ( 16 / 14 ) + 4.00
Note: I is output current value 4 mA≤I≤20 mA
D is pH value displayed by the instrument 0.00pH≤D≤14.00pH

2. Formula of ORP current output:
Factory setting define the output current is :-2000mV is corresponding
value of 4 mA; +2000mV is corresponding value of 20 mA.
I = ( D - 4 mA corresponding value )× ( 16 / (20 mA corresponding value - 4 mA corresponding value) ) + 4.00
I = ( D – (-2000) )× ( 16 / (+2000 – (-2000)) ) + 4.00
I = ( D + 2000 )× ( 16 / 4000) ) + 4.00
Note:I is output current value 4 mA≤I≤20 mA
D is ORP value displayed by the instrument -2000mV≤D≤+2000mV








Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

What is JIRS PH/ORP-6800 controller used for?

Down Down

It is a single-channel industrial online water quality controller, supporting either pH or ORP continuous real-time monitoring and automatic control. Widely applied in municipal wastewater, chemical industry, printing & dyeing, electroplating, swimming pool, aquaculture and environmental water treatment projects.

Can this machine test pH and ORP at the same time?

Down Down

No. It only has one probe input port. You can install pH probe for pH measurement or ORP probe for ORP detection separately, cannot monitor two parameters simultaneously.

What power supply options does PH/ORP-6800 support?

Down Down

Multiple global universal power options: AC220V, AC110V, AC24V, DC24V, meeting different industrial power standards worldwide. Power consumption ≤3W, low energy cost.

What is the installation size of the controller?

Down Down

Outer dimension: 96×96×100mm; Panel cutout size: 92×92mm, standard panel mounting design, easy to install on control cabinets.
ORP-6800-                  
       
                

Related Products

right
right
RO Membrane

RO Membrane

PH-6800

PH-6800

WS-9200/9250

WS-9200/9250

RO-8100

RO-8100

RO- 8200

RO- 8200

ORP-6800

ORP-6800

PH/ORP-600

PH/ORP-600

JIRS-803C

JIRS-803C

Related News

right
right
Rotameter FAQ for small-flow measurement in water treatment

Nov.03,2026

Rotameter FAQ for small-flow measurement in water treatment

Learn how a Rotameter measures fluid flow, where it fits in water-treatment and RO systems, and which accuracy, pressure, and float details to review before ordering.

Choosing WS 9100: Application Fit and Specification Checks

Oct.29,2026

Choosing WS 9100: Application Fit and Specification Checks

Evaluate whether the WS 9100 fits your environmental monitoring project. Review power supply options, temperature-controlled storage, sampling method compatibility, and key specifications before purchasing.

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

Oct.23,2026

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

PH/ORP-6850 FAQ: pH 0–14 and ORP ±1200 mV ranges, ±0.02 pH accuracy, isolated 4–20 mA output, relay alarms, power supply options and panel installation.

Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish