It has the characteristics of simple structure, intuitive, small pressure loss, and easy maintenance. The Rotameter is suitable for measuring small flows through pipes with a diameter of D<150mm, and can also measure the flow of corrosive media.

Main Specifications

  • • Working Pressure:≤ 0.6MPa
  • • Operating Temperature:0~60℃
  • • Accuracy:±4%
  • • Body Material: Acrylic
  • • Fitting Material :ABS or SS
  • • Float Material: SS
  • • O-ring Material: Silicon rubber
  • • The fixed screw of center distance F is M6×11.
  • • Customized specifications are available
  • • When the flow meter is equipped with external threads, the total length is A, When the flow meter is equipped with internal threads, the total length is B.

Installation Method

RotaMeter has a simple structure and is generally installed vertically on a panel or a vertical pipe section. It is suitable for measuring the flow of low-velocity and low-flow media, but cannot measure media with more impurities. The fluid medium passes through the rotor flow meter from bottom to top.

1.Panel mounted Rotameter:

The LZM series Panel Rotameter is generally installed on the control panel, with both the inlet and outlet located at the back. Therefore, before installation, the inlet and outlet connection ports and the instrument fixing screw holes need to be in an open state.

RotameterRotameter

 

1.1 Material:

Body

Fitting

Adjust Valve

O-ring

 

√ Acrylic

 

√ 1 .ABS     4. PA

2. PP      5. Brass(chrome plate) 

3. PVC     6. SS

√ 1.SS

1. Acrylic

2. PTFE

√  1.Silicon rubber

 2.Fluororubber

3.EPDM

Note:

Mark with √, the material of the Flow Meter is the General Configuration.

1.2 Technical Parameters:

Model

Range

Nm³/h(Gas)

Screw Thread

Accuracy

Size(mm)

GPM(Liquid)

(Gallon/Min)

LPM(Liquid)

(L/Min)

A

B

C

D

E

F

G

Hole size

LZM-15

0.05~0.5

0.1~1

0.2~2

0.3~3

0.5~5

0.2~2

0.5~4

1~7

1~11

2~18

10~100LPH

16~160LPH

25~250LPH

0.1~1

0.2~2

0.5~3

0.6~6

1.2~12

1.6~16

2.5~25

1~10

(Male)

1/2"BSPT

(Female)

1/4"BSPT

±4%

176

32

168

35

19

76

127

26

LZM-25

1~10

2~15

2~20

3~30

5~35

5~40

5~40

10~50

10~70

10~110

20~140

10~150

6~60m³/h

16~160m³m/h

25~250Nm³/h

(Male)

1"BSPT

234

45

226

46

27

100

160

38

LZM-50

5~45

10~50

10~60

20~80

25~100

30~150

10~170

50~190

20~220

90~300

100~350

100~500

 

(Male)

2"BSPT

296

70

281

82.5

41

100

190

64

2.Pipeline Installation Rotameter:

The LZM-G Pipeline series Rotameter can be directly connected in a pipeline, with the inlet and outlet located at the upper and lower ends of the flow meter. The shape can be circular, square, or other polygonal forms (generally, the most commonly used is circular). The connection thread can be either external or internal, and the specifications and materials of the threads can be customized according to requirements.

RotameterRotameter

Internal Thread

Appearance Diagram

External Thread

Appearance Diagram

 

2.1 Material:

Body

Fitting

Float

O-ring

√ 1. PC

2.PSU

3. AS

√ 1 .ABS  4. Brass

2. PP   5. Brass(chrome plate)

3. PVC  6. SS

√ 1.SS

√  1.Silicon rubber

2.Fluororubber

3.EPDM

Note:

Mark with √, the material of the Flow Meter is the General Configuration.

2.2 Technical Parameters:

Model

Range

Nm³/h(Gas)

Screw Thread

Accuracy

Size(mm)

GPM(Liquid)

(Gallon/Min)

LPM(Liquid)

(L/Min)

A

B

C

D

LZM-15G

0.05~0.5

0.1~1

0.15~1.5

0.2~2

0.25~2.5

0.3~3

0.5~5

0.18~1.8

0.4~4

0.5~5.5

1~7

1~9

1~11

1.8~18

0.8~8

1~10

1.2~12

1.6~16

2.5~25

6~60LPM

(External)

G1/2"

1/2"BSP

(Internal)

G1/2"

1/2"BSP

±4%

235

233

180

32

LZM-20G

1~10

1.5~15

2~20

3~30

5~35

4~40

4~40

5~55

10~70

10~110

20~140

15~150

4~40

6~60

(External)

G1/¼"

1//¼"BSP

(Internal)

G3/4"

3/4"BSP

330

283

236

45

LZM-25G

1~10

2~20

3~30

5~35

4~40

5~50

6~60

4~40

10~70

10~110

20~140

15~150

25~190

30~225

15~140

16~160

25~250

40~400

(External)

G1/½"

1//½"BSP

(Internal)

G1"

1"BSP

319

297

235

51

LZM-40G

4~40

6~60

20~80

15~100

 

15~150

22~220

30~300

50~400

 

(Internal)

G1/½"

1/½"BSP

340

302

240

65

LZM-50G

20~80

20~100

20~120

40~150

60~200

100~300

100~350

100~450

150~550

150~750

100~500

100~600

300~900

(External)

G2"

2"BSP

(Internal)

G2"

2"BSP

400

367

294

75

3. Rotameter Pictures:

RotameterRotameterRotameter

4.Rotameter Application:

Due to various excellent performance and reliability,the Rotameters are widely used in chemical, pharmaceutical, paper making, water treatment, RO water purify equipment etc.

RotameterRotameter

 

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

Frequently Asked Questions (FAQ) About Rotameter

What is the use of 2W series solenoid valve?

Down Down

Used to control fluid on-off and other operations.

How to install 2W series solenoid valve?

Down Down

Install and wire at appropriate location according to instructions.

How to use 2W solenoid valve correctly?

Down Down

The flow of electricity is controlled according to the process.

What is the cause of the 2W solenoid valve failure?

Down Down

The coil is damaged or the valve core is blocked, etc.
RO reverse osmosis membrane-14.webp                  
       
                

Related Products

right
right
RO Membrane

RO Membrane

PH-6800

PH-6800

WS-9200/9250

WS-9200/9250

RO-8100

RO-8100

RO- 8200

RO- 8200

ORP-6800

ORP-6800

PH/ORP-600

PH/ORP-600

JIRS-803C

JIRS-803C

Related News

right
right
Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.

Industrial TDS Controller Machine for Water Quality Management

Jun.23,2026

Industrial TDS Controller Machine for Water Quality Management

Maintaining precise water purity is critical for various industrial, agricultural, and domestic applications. A tds controller machine serves as the brain of a water treatment system, continuously monitoring Total Dissolved Solids TDS to ensure that water quality remains within specified limits. Whether you are managing a hydroponic farm, a pharmaceutical lab, or a large-scale reverse osmosis plant, having an automated way to regulate mineral concentrations is essential for efficiency and product consistency. In this guide, we will explore how these machines work and why they are indispensable for modern water management.

Optimize Water Purity with a TDS Controller in RO System

Jun.21,2026

Optimize Water Purity with a TDS Controller in RO System

Maximizing Water Purity: The Role of a TDS Controller in RO System Achieving consistent water quality is the primary goal of any reverse osmosis setup. A tds controller in ro system acts as the brain of the filtration process, monitoring Total Dissolved Solids TDS in real-time to ensure the output meets specific purity standards. Without precise control, users often face the dilemma of either wasting too much water or compromising on the purity of the drinking or process water. By integrating an intelligent controller, you can automate the blending process, extending the life of your membranes while maintaining a perfect balance of minerals.

Optimize Water Quality Using a tds controller for ro Systems

Jun.20,2026

Optimize Water Quality Using a tds controller for ro Systems

Optimizing Water Purity with a TDS Controller for RO Systems Maintaining the ideal balance of minerals in purified water is critical for both industrial processes and residential health. A tds controller for ro acts as the brain of a Reverse Osmosis system, ensuring that Total Dissolved Solids TDS remain within a precise range. Without an effective controller, RO systems can either strip too many essential minerals or allow contaminants to leak through as membranes age. This guide explores how these devices function, their importance in water treatment, and how to choose the right model for your specific needs to ensure consistent water quality.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish