JIRS-803C4

This sampler can collect water samples from sewage wells up to 10 meters deep. Powered by a lithium battery, it comes with a 3L sampling bottle and can be configured with the app.

Product Details

Product Details

Contact Now

Contact Now

Product Details


Product Paramenters

Work EnvironmentMaximum depth 15 meters
Single sampling volume10-3000ml (adjustable)
Sampling bucket capacity3L
Sampling interval2min-9999min (adjustable)
Sampling volume error±7%
Supply voltage

DC24V

Battery capacity

10Ah

Overall dimensions (length × width × height)

225mm×225mm×610mm

Operating temperature5°C~40°C
Machine weight (without water)≤6kg
Protection levelIP68

 

Function Features

Automatic sampling functionThe instrument can realize automatic sampling in time proportion, and the single sampling volume and sampling times can be set;
Automatic emptying functionWhen the instrument selects the automatic sampling function, the system can automatically drain the water in the tube before and after each sampling to ensure that the sampling pipeline is not blocked by sedimentation;
Automatic rinse functionThe sampler can automatically rinse the sampling pipeline before each sampling to ensure that the samples collected each time do not interfere with each other;
Water leak detectionWhen water leakage occurs in the instrument, the instrument will automatically stop running and alarm;
Battery poweredThe sampler is powered by a built-in lithium battery. When fully charged, it can work normally for 5 consecutive days.
Sampling recordsCan store 1000 records.
APP controlSampling control and parameter setting can be performed through the mobile phone APP;
Multiple ways to useSupports external battery and optional wellhead bracket.

 

Application Overview

        The DR-803C4 automatic water sampler is a hanging automatic water sampler for use in sewage wells. Featuring a built-in lithium battery, it is compact, lightweight, and easy to carry. It features one-touch operation and automatically stops sampling when the set sampling volume is reached. It is ideal for long-term, unattended sampling of sewage wells by third-party testing companies, monitoring agencies, urban construction departments, and water authorities.

 

 

 

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

Frequently Asked Questions FAQ About Water Sampler

How does the DR-803C4 automatic water sampler prevent cross-contamination between samples?

Down Down

The DR-803C4 features a 3-stage cleaning system: Pre-sampling rinse: Auto-rinses tubing with fresh water (adjustable 1-99 sec); Post-sampling drain: Fully evacuates residual liquid via patented siphoning tech; UV sterilization (optional): For microbiological sampling applications

What makes the DR-803C4 suitable for deep-well sampling (up to 10m)?

Down Down

Key engineered solutions: Pressurized intake system: Maintains 0.3MPa suction at max depth; Military-grade cables: Kevlar-reinforced with IP68 waterproof connectors; Tilt compensation: ±15° auto-adjustment to ensure vertical sampling.

Can the sampler operate during power outages?

Down Down

Yes, with 3 backup modes: 1. 10.4Ah Li-ion battery: 120hr standby / 5-day continuous operation; 2. Solar-ready (24V DC input); 3. Emergency manual sampling via mechanical override.

How does the leakage protection work?

Down Down

The TripleSafe™ system detects: Water ingress: Optical sensors trigger instant shutdown; Tube cracks: Flow rate monitoring (±7% tolerance); Battery shorts: Galvanic isolation circuitry.

What maintenance does the peristaltic pump require?

Down Down

300-500 hour service cycle: Monthly: Check tube elasticity (≥85% rebound rate); Quarterly: Replace OEM pump tubes (PN: DR-TUBE-803C); Annual: Lubricate roller assembly (FDA-grade grease included).
1                  
       
                

Related Products

right
right
RO Membrane

RO Membrane

PH-6800

PH-6800

WS-9200/9250

WS-9200/9250

RO-8100

RO-8100

RO- 8200

RO- 8200

ORP-6800

ORP-6800

PH/ORP-600

PH/ORP-600

JIRS-803C

JIRS-803C

Related News

right
right
Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.

Industrial TDS Controller Machine for Water Quality Management

Jun.23,2026

Industrial TDS Controller Machine for Water Quality Management

Maintaining precise water purity is critical for various industrial, agricultural, and domestic applications. A tds controller machine serves as the brain of a water treatment system, continuously monitoring Total Dissolved Solids TDS to ensure that water quality remains within specified limits. Whether you are managing a hydroponic farm, a pharmaceutical lab, or a large-scale reverse osmosis plant, having an automated way to regulate mineral concentrations is essential for efficiency and product consistency. In this guide, we will explore how these machines work and why they are indispensable for modern water management.

Optimize Water Purity with a TDS Controller in RO System

Jun.21,2026

Optimize Water Purity with a TDS Controller in RO System

Maximizing Water Purity: The Role of a TDS Controller in RO System Achieving consistent water quality is the primary goal of any reverse osmosis setup. A tds controller in ro system acts as the brain of the filtration process, monitoring Total Dissolved Solids TDS in real-time to ensure the output meets specific purity standards. Without precise control, users often face the dilemma of either wasting too much water or compromising on the purity of the drinking or process water. By integrating an intelligent controller, you can automate the blending process, extending the life of your membranes while maintaining a perfect balance of minerals.

Optimize Water Quality Using a tds controller for ro Systems

Jun.20,2026

Optimize Water Quality Using a tds controller for ro Systems

Optimizing Water Purity with a TDS Controller for RO Systems Maintaining the ideal balance of minerals in purified water is critical for both industrial processes and residential health. A tds controller for ro acts as the brain of a Reverse Osmosis system, ensuring that Total Dissolved Solids TDS remain within a precise range. Without an effective controller, RO systems can either strip too many essential minerals or allow contaminants to leak through as membranes age. This guide explores how these devices function, their importance in water treatment, and how to choose the right model for your specific needs to ensure consistent water quality.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish