EC/TDS/RM-6850

EC/TDS/RM-6850 online Conductivity / TDS / Resistivity controller can continuously measure and control conductivity/ TDS / Resistivity value of water.

Product Details

Product Details

Contact Now

Contact Now

Product Details

Main Features

  • * English language display
  • * Measure Conductivity/TDS/Resistivity and Temperature,
  • * High/low limit relay control output , 4-20mAcurrent output, digital Modbus RS485 communication output (Optional)
  • * High/low limit alarm light, double relay, alarm delay could be set
  • * Instrument mode isolated transmitting port, max circle resistance up to 750Ω
  • * PID control to actuate and control powered variable value through 4-20 mA output (optional)
  • * Back light of LCD could select power saving mode, timing automatic off, brightness adjust,
  • * Conductivity constant input directly function or to calibrate probe constant as per known calibration solution’s conductivity value
  • * High performance CPU, good electromagnetic compatibility
  • * MOV and AC input be fused function
  • * ESD over voltage protection is available
  • * Password management avoid non-professional person to operate

Application

It is widely used for the seawater desalination, aquaculture, reverse osmosis, chemical, pharmaceutical, environmental protection, metallurgy, paper making, food, beverage, water supply industry, science laboratory equipment, and all kinds of water treatment facility online monitoring and controlling.

Main Technique Specification

 

EC, TDS, RM-6850 Conductivity /TDS /Resistivity controller

Measuring Range

Conductivity:

0-200uS ( 0.1sensor),

0-20, 000uS(1.0 sensor),

0-200mS (10.0 sensor), 0-600mS(30.0 sensor)

TDS:

0-100ppm(0.1 sensor),

0-10,000ppm(1.0/10.0 sensor)

0-99,999ppm (10.0 sensor)

Resistivity:

0-18.25MΩ·cm  (0.01 sensor)

0-18250KΩ·cm  (0.01 sensor)

Accuracy

+ 1.5% (FS)

Temp. Comp.

0~120 ℃, Automatic, PT1000

Sensor constant:

0.01, 0.1, 1.0, 10.0, 30.0 cm-1,

Sensor connection:

1/2”NPT (standard), 3/4”NPT(optional), Flanged (optional)

Sensor cable length

5m or as per request

Display

128 * 64 dot matrix LCD

Current output signal

Isolated, Transferable 4-20mA signal output,

max circle resistance 750Ω

Control output signal

High/Low Limit relay control output, (3A/250 V AC)

Communication signal

Modbus RTU RS485 (optional)

Power

AC 220V ±10%, 50Hz (Standard)

AC110V ±10%, 50Hz (Optional)

AC/DC 24V(optional)

Working temperature.

0~60℃, 0~100℃ (Match high temp. Sensor)

Working pressure:

0~0.5MPa

Protection grade:

IP 65

Working environment

Ambient Temp. 0~60℃, Relative Humidity ≤95%

Overall dimensions

96×96×127mm(high×width×depth)

Hole dimensions

92×92mm(height×width)

Installation Mode

Panel Mounted(Embeded)

Conductivity TDS And Resitivity Display

EC/TDS/RM-6850

 

EC/TDS/RM-6850

 

EC/TDS/RM-6850

 

EC/TDS/RM-6850 EC/TDS/RM-6850 EC/TDS/RM-6850

 

Matched Conductivity, Resistivity Sensor, 1/2”, 3/4”NPT or Flanged

EC/TDS/RM-6850

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

Frequently Asked Questions (FAQ) About TDS

What is this controller and what scenarios is it mainly used for?

Down Down

Is a conductivity/TDS/resistivity controller for water quality monitoring etc.

How do I install a controller like Online Conductivity?

Down Down

Choose a location to install the probe, connect the lines and complete debugging.

How to maintain and calibrate this controller?

Down Down

Calibrate regularly, clean the probe, and check the wiring connections.

What is the reason for the inaccurate measurement of this controller?

Down Down

Probe failure, calibration error, environmental factors.
EC-6850.webp                  
       
                

Related Products

right
right
WS-9300/9350

WS-9300/9350

WS-9200/9250

WS-9200/9250

WS-9200/9250

WS-9200/9250

JIRS-803C

JIRS-803C

JIRS-803C3

JIRS-803C3

JIRS-803C4

JIRS-803C4

JIRS-803C5

JIRS-803C5

Soil Sensor

Soil Sensor

Related News

right
right
Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.

Industrial TDS Controller Machine for Water Quality Management

Jun.23,2026

Industrial TDS Controller Machine for Water Quality Management

Maintaining precise water purity is critical for various industrial, agricultural, and domestic applications. A tds controller machine serves as the brain of a water treatment system, continuously monitoring Total Dissolved Solids TDS to ensure that water quality remains within specified limits. Whether you are managing a hydroponic farm, a pharmaceutical lab, or a large-scale reverse osmosis plant, having an automated way to regulate mineral concentrations is essential for efficiency and product consistency. In this guide, we will explore how these machines work and why they are indispensable for modern water management.

Optimize Water Purity with a TDS Controller in RO System

Jun.21,2026

Optimize Water Purity with a TDS Controller in RO System

Maximizing Water Purity: The Role of a TDS Controller in RO System Achieving consistent water quality is the primary goal of any reverse osmosis setup. A tds controller in ro system acts as the brain of the filtration process, monitoring Total Dissolved Solids TDS in real-time to ensure the output meets specific purity standards. Without precise control, users often face the dilemma of either wasting too much water or compromising on the purity of the drinking or process water. By integrating an intelligent controller, you can automate the blending process, extending the life of your membranes while maintaining a perfect balance of minerals.

Optimize Water Quality Using a tds controller for ro Systems

Jun.20,2026

Optimize Water Quality Using a tds controller for ro Systems

Optimizing Water Purity with a TDS Controller for RO Systems Maintaining the ideal balance of minerals in purified water is critical for both industrial processes and residential health. A tds controller for ro acts as the brain of a Reverse Osmosis system, ensuring that Total Dissolved Solids TDS remain within a precise range. Without an effective controller, RO systems can either strip too many essential minerals or allow contaminants to leak through as membranes age. This guide explores how these devices function, their importance in water treatment, and how to choose the right model for your specific needs to ensure consistent water quality.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish