JIRS-803C5

This automatic water sampler can be used as an outdoor sampler for pollution sources, rivers, and lakes. It has the characteristics of small size, easy portability, and multiple sampling modes. It can be applied in multiple scenarios such as third-party testing, biological testing, drug testing, and environmental law enforcement testing.

Product Details

Product Details

Contact Now

Contact Now

Product Details

Product Paramenters

Sampling interval 1~9999min(adjustable)
Number of sampling bottles 1 bottle, capacity: 3L, material: PE
Single sampling volume 1~2500mL
Sampling error 士7%
Proportional sampling error ±8%
Sampling vertical height

≥6.5 meter

Horizontal sampling distance

≥65 meter

Piping system air tightness

≤-0.085MPa

Water sample refrigeration temperature (0~5)°C
Mean time between failures ≥1440h/time
Powered Supply AC220V±10%, frequency 50Hz±1%
Built-in battery Can run for more than 6 hours in case of power failure (no sampling and no cooling)
Operating temperature 5°C~40℃
Operating humidity ≤90%RH (no condensation)
Data storage capacity Sampling records ≥ 1000, alarm records ≥ 1000
Dimensions 450mmx345mmx540mm

 

Function Features

Usage Portable sampler, powered by mains electricity (can be powered by outdoor AC220V power supply);
Multiple sampling modes It can realize timing sampling, time proportional sampling, flow proportional sampling and external control sampling;
Multiple sampling methods Single sampling and mixed sampling;
Fixative Addition Automatically add one type of fixative, configurable (sulfuric acid, hydrochloric acid, nitric acid, NaOH, etc.).
Water Sample Refrigeration A refrigerator is available to refrigerate water samples.
Sampling Recording Records sampling date and time, sampling mode, sampling volume, fixed dose, and whether the sampling was successful. Records up to 1,000 data entries, with page-by-page navigation;
Power Outage Recording Records power outage and power-on times, with up to 1,000 records and page-by-page browsing;
Alarm recording function Record alarm information and be able to query alarm time and status.
Power-off Protection If the instrument is powered off and then back on while in operation, the sampler's previously set parameters, sampling history, and other information are retained.
Automatic Drain Function After each sampling session, the system automatically drains the water in the tube to prevent sedimentation and blockage;
Rinse Function Before each sampling session, the system automatically rinses the tube with the water sample to be collected, ensuring that each sample does not interfere with another;
Video Recording Function (Optional) Captures video of the sampler top and inlet for remote viewing;
Remote Communication Function (Optional) Equipped with a mobile app for remote control.
GPS Positioning Function (Optional) The device features built-in GPS positioning, allowing for the setting of electronic fences and automatic alarms when exceeding a specified area;
Wireless Transmission Function (Optional) Equipped with a 4G DTU, the device can be remotely monitored and controlled.

 

Application Overview

   

        The DR-803C5 automatic water sampler utilizes embedded control technology and offers multiple sampling modes, including timed sampling, time-proportional sampling, flow-proportional sampling, and externally controlled sampling. It also features single-shot and mixed sampling. It also includes features such as leak alarm, video recording, sample refrigeration, and power-off protection, making it an intelligent automatic water sampler.

        It can be widely used for sampling pollution sources, rivers, and lakes. Its compact size, portability, ease of use, and versatile operation make it particularly suitable for on-site environmental law enforcement and mixed sampling by disease control departments.

 

 

 

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

Frequently Asked Questions FAQ About Water Sampler

What sampling modes does the DR-803C5 water sampler support?

Down Down

The DR-803C5 offers four professional sampling modes for different scenarios: timed sampling for fixed intervals, time-proportional sampling for consistent time gaps, flow-proportional sampling triggered by water meter data, and external control sampling through dry contact signals. All modes maintain sampling accuracy within 7 error margin.

How does the DR-803C5 ensure sample integrity during outdoor operation?

Down Down

This industrial sampler features multiple protection systems including automatic tube rinsing before each sample, complete drainage after sampling, and refrigerated storage at 0-5°C. The polypropylene sampling bottle and food-grade tubing prevent chemical absorption while the IP66-rated housing protects against rain and dust.

Can the sampler operate during power outages?

Down Down

Yes, the DR-803C5 has three backup solutions: its built-in 10.4Ah lithium battery supports 5 days continuous operation, optional solar panel compatibility, and emergency manual sampling mode. The system automatically resumes interrupted sampling cycles when power restores.

What maintenance does the peristaltic pump require?

Down Down

The precision pump tubes require replacement every 300-500 operating hours. We recommend checking tube elasticity monthly and replacing every 3-5 months depending on water quality. Use only genuine DR-TUBE-803C replacement tubes to maintain the 7 accuracy guarantee.

How does remote monitoring work through the mobile app?

Down Down

The Android/iOS app connects via 4G to provide real-time GPS tracking, sampling data access, and video monitoring of the intake. Users can adjust sampling parameters remotely and receive instant alerts for leaks or power failures. The system stores 1000+ records locally as backup.
1                  
       
                

Related Products

right
right
WS-9300/9350

WS-9300/9350

WS-9200/9250

WS-9200/9250

WS-9200/9250

WS-9200/9250

JIRS-803C

JIRS-803C

JIRS-803C3

JIRS-803C3

JIRS-803C4

JIRS-803C4

JIRS-803C5

JIRS-803C5

Soil Sensor

Soil Sensor

Related News

right
right
Guide to Choosing the Right RO Controller for Water Purification

Apr.16,2026

Guide to Choosing the Right RO Controller for Water Purification

Maintaining a high-performance reverse osmosis system requires more than just quality membranes; it demands precise regulation. An ro controller serves as the brain of the entire operation, monitoring critical parameters such as conductivity, temperature, and flow rates to ensure the output water meets stringent purity standards. Without an efficient controller, systems are prone to membrane fouling, inefficient energy use, and inconsistent water quality. In this comprehensive guide, we will explore how these devices optimize water treatment processes and how to select the best model for your specific industrial or commercial needs.

Guide to Water Purity Using RO with TDS Controller Systems

Apr.09,2026

Guide to Water Purity Using RO with TDS Controller Systems

Achieving the perfect balance of mineral content and purity in drinking water is a challenge for many households and industrial facilities. A ro with tds controller offers a sophisticated solution by combining the rigorous filtration of Reverse Osmosis (RO) with the precision of a Total Dissolved Solids (TDS) adjustment system. While standard RO systems remove almost everything, including beneficial minerals, a TDS controller allows users to re-mineralize the water to a desired level. This ensures that the water is not only safe and pure but also tastes better and provides essential nutrients.

Understanding and Optimizing Reverse Osmosis Systems with a Controller

Apr.07,2026

Understanding and Optimizing Reverse Osmosis Systems with a Controller

In the world of water purification, reverse osmosis (RO) systems are a cornerstone for producing high-quality water for various applications, from drinking water to industrial processes. However, an RO system is only as effective as its control system. This is where the reverse osmosis controller comes into play. This critical component manages and optimizes the RO process, ensuring efficient operation, water quality, and system longevity.

Understanding the Vital Role of an RO System Controller for Optimal Performance

Apr.04,2026

Understanding the Vital Role of an RO System Controller for Optimal Performance

Reverse Osmosis (RO) systems are critical for purifying water across various industries, from residential applications to large-scale industrial processes. At the heart of a well-functioning RO system lies the RO system controller. This intelligent device monitors and regulates all key parameters of the RO process, ensuring optimal performance, efficiency, and water quality. This article delves into the functionalities, benefits, and selection criteria for choosing the right RO system controller, particularly focusing on those offered by Watequipments. Understanding its role is crucial for maximizing the lifespan and effectiveness of your RO investment.

Smart Water Treatment Solutions Using PH ORP Controller Systems

Mar.24,2026

Smart Water Treatment Solutions Using PH ORP Controller Systems

In modern water treatment and industrial fluid management, maintaining precise chemical balance is essential for safety, efficiency, and regulatory compliance.

Comprehensive Guide to Water Depth Samplers and Their Applications

Mar.04,2026

Comprehensive Guide to Water Depth Samplers and Their Applications

Accurate water quality monitoring is crucial in various fields, from environmental science and aquaculture to industrial wastewater management. A key tool for this is the water depth sampler. This article provides an in-depth look at water depth samplers, their applications, types, and essential considerations for choosing the right one for your needs. We'll explore the benefits of utilizing this equipment to collect reliable data for analysis and informed decision-making. Selecting the right sampler can significantly improve the precision and efficiency of your water monitoring program. A water depth sampler, also known as a depth-integrated sampler, is a device designed to collect water samples from specific depths within a body of water. Unlike simply dipping a container into the water, a depth sampler allows for collection of a representative sample across a defined depth range. This is critical because water properties (temperature, salinity, pollutants) often vary significantly with depth. The data gathered with a water depth sampler provides a more accurate assessment of water quality than surface samples alone.

Comprehensive Guide to Horizontal Water Sampler Applications and Selection

Mar.03,2026

Comprehensive Guide to Horizontal Water Sampler Applications and Selection

Collecting water samples at varying depths is crucial for environmental monitoring, research, and quality control. The horizontal water sampler from Watequipment.com offers a precise and efficient solution for this task. This article provides an in-depth look at horizontal water samplers, their applications, benefits, and key considerations when choosing the right model. We will explore how these samplers contribute to accurate data collection and informed decision-making in various fields. A horizontal water sampler is a device designed to collect water samples from specific depths within a body of water – rivers, lakes, oceans, reservoirs, and even wastewater treatment plants. Unlike vertical samplers which primarily focus on depth, horizontal samplers prioritize collecting samples at a consistent depth while moving along a horizontal plane. This is essential for assessing water quality variations across a waterway or within a specific zone. They are used in applications ranging from environmental monitoring and scientific research to industrial process control and regulatory compliance.

Comprehensive Guide to Selecting the Right Surface Water Sampler for Your Needs

Feb.28,2026

Comprehensive Guide to Selecting the Right Surface Water Sampler for Your Needs

Monitoring the quality of surface water is critical for environmental protection, public health, and various industrial applications. A surface water sampler is an essential tool for collecting representative samples from rivers, lakes, ponds, and other surface water sources. This article provides a detailed overview of surface water samplers, their types, applications, and key considerations for selecting the right equipment. Accurate water quality data relies on proper sample collection, and choosing the correct sampler is the first step toward achieving reliable results. Surface water samplers come in various designs, each suited to specific sampling needs. Common types include grab samplers, depth-integrating samplers, peristaltic pumps, and automatic samplers. Surface water samplers are used across a broad spectrum of applications, including environmental monitoring, wastewater discharge monitoring, drinking water source monitoring, agricultural runoff analysis, and research studies.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish