Pressure Switch

The LF55 pressure switch is an automatic control device that responds to pressure signals and operates accordingly. It can serve as a safety protection measure in various devices such as pumps, hydraulic systems, and hydraulic machinery. Provide international standard mounting bracket for any part. SPDT switch ensures reliable contact switching. The pressure bellows of the standard model are phosphor bronze bellows, the pressure port is made of brass.

Product Details

Product Details

Contact Now

Contact Now

Product Details


Introduction

 

  • • The LF55 pressure switch is an automatic control device that responds to pressure signals and operates accordingly.
  • • It can serve as a safety protection measure in various devices such as pumps, hydraulic systems, and hydraulic machinery.
  • • Provide international standard mounting bracket for any part.
  • • SPDT switch ensures reliable contact switching.
  • • The pressure bellows of the standard model are phosphor bronze bellows, the pressure port is made of brass.

 

Working principle

By adjusting the screw of the pressure switch, the spring tension can be adjusted. The deeper the screw is screwed in, the greater the spring force that the measuring element must overcome, and the switch point value correspondingly increases. The geometric structure of the spring is designed according to the required switching range. According to the functional principle of mechanical pressure switches, the switching point is defined by the spring pre-tension, which sets the switching point when the pressure increases. When the external pressure acts on the pressure sensing element as the pressure decreases, the spring or diaphragm deforms accordingly. When the pressure reaches a certain level, the deformation of the spring or diaphragm causes a displacement in the mechanical structure, thereby closing or opening the contacts and changing the conductivity state of the circuit.

Widely used for reverse osmosis systems.

Pressure Switch

 

Specification

 

Pressure Switch

120V AC

250V AC

Non-induced Current

20A

10A

Induced Current

Full-load

15A

8A

Momentary

72A

 

Notice

Use two spanners to avoid damaging the controller; Install to the equipment by four M4 screws on back side of the controller directly; Use multi-purpose mounting plate, it is also easy to install. Please use screws in attachment bag when installing.

 

Model

Range(bar)

Differential (bar)

Factory Setting

(bar)

Max Airtight Test
Pressure(bar)

Min.

Max.

Min.

Max.

OFF

ON

LF5502

-0.5

2

0.2

0.7

1

0.5

16.5

LF5503

-0.5

3

0.35

1.5

2

1

16.5

LF5506

-0.5

6

0.6

4

3

2

16.5

LF5506M

-0.5

6

Reset differential≤1bar

3

Manual Reset

16.5

LF5510

1

10

1

3

6

5

16.5

LF5516

3

16

1

4

10

8

35

LF5520

5

20

2

5

16

13

35

LF5530

8

30

Fixed 3-5

20

15~17

35

LF5530M

8

30

Reset differential≤4bar

20

Manual Reset

35

LF5530D

5

30

3

10

20

15

35

LF5532

8

32

2

6

20

17

35

LF5542

8

42

4

10

30

25

46.5

 

Scale plate:two units-“bar”&“psig”;“MPa”&“Kgf/cm2”are also available;

British thread model can add“E”according to custom requirement,

Also wilding model add“C”, capillary model add“S”,such as LF5506E;

Ammonia refrigerant model add“B”,such as LF5506B.

 

Dimension

Pressure Switch

Pressure Switch

Pressure Switch

 

 

 

Wiring Instructions

Pressure SwitchPressure Switch

 

Pressure Switch Pictures

 

Pressure SwitchPressure Switch
Pressure SwitchPressure Switch

External Thread: G 1/4”

(Standard Version)

External Thread: 7/16-20”

(Optional Version)

 

Installation Picture

 

Pressure SwitchPressure Switch

 

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

Frequently Asked Questions (FAQ) About Pressure Switch

What is the main purpose of a pressure switch?

Down Down

Used to monitor and control pressure.

How to install pressure switching equipment?

Down Down

Secure and wire in place.

How to operate the pressure switch correctly?

Down Down

Adjust the pressure action according to the set value.

What are the causes of pressure switch failure?

Down Down

The diaphragm is damaged or the contacts are in poor contact.
ai (1).webp                  
       
                

Related Products

right
right
RO Membrane

RO Membrane

PH-6800

PH-6800

WS-9200/9250

WS-9200/9250

RO-8100

RO-8100

RO- 8200

RO- 8200

ORP-6800

ORP-6800

PH/ORP-600

PH/ORP-600

JIRS-803C

JIRS-803C

Related News

right
right
Rotameter FAQ for small-flow measurement in water treatment

Nov.03,2026

Rotameter FAQ for small-flow measurement in water treatment

Learn how a Rotameter measures fluid flow, where it fits in water-treatment and RO systems, and which accuracy, pressure, and float details to review before ordering.

Choosing WS 9100: Application Fit and Specification Checks

Oct.29,2026

Choosing WS 9100: Application Fit and Specification Checks

Evaluate whether the WS 9100 fits your environmental monitoring project. Review power supply options, temperature-controlled storage, sampling method compatibility, and key specifications before purchasing.

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

Oct.23,2026

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

PH/ORP-6850 FAQ: pH 0–14 and ORP ±1200 mV ranges, ±0.02 pH accuracy, isolated 4–20 mA output, relay alarms, power supply options and panel installation.

Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish