The PH/ORP-600 is a professional-grade, cost-effective industrial online monitor specifically engineered for continuous water quality surveillance. Designed to maintain long-term stability within the most demanding industrial environments, this versatile controller supports both pH and ORP measurements. With high input impedance, it is fully compatible with most standard pH/ORP composite electrodes, making it an ideal solution for sewage treatment plants and high-purity water systems.

Integrating advanced EMC anti-jamming circuitry, the PH/ORP-600 ensures precise data acquisition even in electrically noisy settings. Its compact panel-embedded design allows for seamless installation into existing control systems, while the dual-power supply options and wide humidity tolerance ensure operational reliability across various chemical and water treatment applications.

Detailed Parameters

Measurement RangepH (0-14 pH) / ORP (-1200 to +1200 mV)Resolution0.01 pH / 0.2 mV
Accuracy± 0.1 pH / ± 1 mVDisplay ModeHigh-clarity LCD
CalibrationThree-point auto-calibrationStandard SolutionspH 4.00/6.86/9.18 (Standard) or 4.01/7.00/10.01 (Optional)
Pressure Resistance0 to 0.5 MPaMax Flow Velocity≤ 3 m/s
Power SupplyAC 220V ±10% / AC 110V ±10% / DC 24V or 12VDimensions48 x 96 x 100 mm (H x W x D)

Key Advantages


Industrial Durability

Built with an advanced EMC anti-jamming circuit for stable performance in harsh industrial environments.


Efficient Calibration

Three-point auto-calibration with automatic standard solution identification for rapid setup.


Precision Control

High-precision relays for high/low limit alarms and precise dosing control via NO contact output.


Versatile Integration

Isolated 4-20mA signal output and optional RS485 Modbus RTU for seamless PLC integration.


Compact Design

Panel-embedded installation saves space while maintaining simple operation and low maintenance.


Broad Compatibility

Matches most common pH/ORP composite electrodes used in pure water and waste systems.

Product Gallery

Management Platforms

Automated Dosing

Utilize high/low limit relays to automate chemical dosing for precise pH balance.

PLC Synchronization

Integrated 4-20mA isolated output for real-time data transmission to central PLC systems.

Alarm Monitoring

Instantaneous alarm triggers via relay contacts when water quality exceeds safety limits.

Remote Communication

Optional RS485 Modbus RTU enables remote monitoring and data logging across the facility.

Temperature Compensation

Manual temperature compensation (0-100°C) ensures accuracy across varying water temps.

Modular Sensor Input

Compatible with 3/4" NPT threaded electrodes for easy replacement and maintenance.

Investment Return Comparison

Feature MetricStandard MonitorsPH/ORP-600 Series
Installation CostHigh (Complex wiring)Low (Compact Panel Mount)
Calibration TimeManual/SlowAuto-ID / Rapid
Signal StabilityProne to interferenceHigh (EMC Shielded)
Maintenance CycleFrequentLong-term Stable
System IntegrationBasic AnalogAdvanced (4-20mA/RS485)

Frequently Asked Questions

Q: How does the PH/ORP-600 handle industrial electrical interference?

The device features an advanced EMC anti-jamming circuit specifically designed to filter out electrical noise, ensuring stable readings in harsh industrial environments.

Q: Can this controller be used for both pure water and sewage?

Yes, the PH/ORP-600 is designed with high input impedance to match a wide variety of composite electrodes suitable for both sewage and pure water systems.

Q: What is the benefit of three-point auto-calibration?

Three-point calibration ensures a more linear and accurate measurement across the entire pH range, while automatic solution identification reduces human error during setup.

Q: How should the sensors be installed for maximum accuracy?

Electrodes should be installed in areas with steady flow speed, submerged deeply, and positioned where air bubbles do not gather to prevent inaccurate readings.

Q: Does the PH/ORP-600 support remote data logging?

Yes, by selecting the optional RS485 Modbus RTU communication module, you can connect the device to a SCADA or remote monitoring system for data logging.

Q: What is the maximum pressure the sensors can withstand?

The measuring electrodes are designed to withstand compression resistance ranging from 0 to 0.5 MPa.

Optimize Your Water Monitoring Process Today

Contact Us

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

                  
       
                

Related Products

right
right
RO Membrane

RO Membrane

PH-6800

PH-6800

WS-9200/9250

WS-9200/9250

RO-8100

RO-8100

RO- 8200

RO- 8200

ORP-6800

ORP-6800

PH/ORP-600

PH/ORP-600

JIRS-803C

JIRS-803C

Related News

right
right
Rotameter FAQ for small-flow measurement in water treatment

Nov.03,2026

Rotameter FAQ for small-flow measurement in water treatment

Learn how a Rotameter measures fluid flow, where it fits in water-treatment and RO systems, and which accuracy, pressure, and float details to review before ordering.

Choosing WS 9100: Application Fit and Specification Checks

Oct.29,2026

Choosing WS 9100: Application Fit and Specification Checks

Evaluate whether the WS 9100 fits your environmental monitoring project. Review power supply options, temperature-controlled storage, sampling method compatibility, and key specifications before purchasing.

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

Oct.23,2026

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

PH/ORP-6850 FAQ: pH 0–14 and ORP ±1200 mV ranges, ±0.02 pH accuracy, isolated 4–20 mA output, relay alarms, power supply options and panel installation.

Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.