CR-102P High-Performance Device – Compact, Reliable, Fast
If you’ve been tracking water quality hardware lately, you’ll have noticed a quiet shift: plants want compact probes with real temperature compensation, quick swap-outs, and materials that don’t panic at CIP chemicals. That’s where the CR-102P keeps popping up in my inbox. It’s straightforward—easy to use, steady readings—and, to be honest, that’s what operators want at 2 a.m. when a line is screaming.
The CR-102P is a conductivity/TDS sensor with an integrated NTC 10K thermistor for automatic temperature compensation. The body is ABS engineering plastic—tough stuff with strong anti-acid and anti-alkaline character—so it survives dosing skids and rinse cycles better than many entry-level probes. Origin, if you care about traceability: No.188, Fengshou Road, Chang'an district, Shijiazhuang, Hebei, China 050041.
| Sensor type | Conductivity/TDS probe with NTC 10K |
| Body material | ABS engineering plastic |
| Chemical resistance | Strong anti-acid/anti-alkaline character (ABS); real-world use may vary |
| Temp compensation | NTC 10K integrated |
| Typical range | ≈0–10 mS/cm (application-dependent; check your controller scaling) |
| Accuracy | ≈±2% of reading in calibrated span |
| Service life | ≈18–36 months typical; harsh chem/heat shortens life |
| Connections | Lead wires or connector options depending on order (confirm at PO) |
Materials: ABS housing, sealed thermistor, corrosion-resistant sensing pins. Methods: two-point or three-point calibration using KCl standards (e.g., 1413 µS/cm and 12.88 mS/cm) following ASTM D1125 guidance. Testing standards we see in specs: ASTM D1125 for conductivity, EPA 120.1 for TDS correlation. Plants usually re-verify monthly; high-crit processes do weekly checks. Service life? In moderate pH and 20–35°C, I see ≈2 years. Hot caustic and steam-in-place? Budget for annual swaps.
Feedback’s pragmatic: “It just holds calibration.” One utility engineer told me drift over 72 hours was ≈0.5% after a fresh two-point, which matches what I’ve seen in labs. Installers like the weight (light), and ABS takes accidental bumps better than brittle lab glass. The trade-off, of course, is you won’t get the ultra-low cell constant precision of premium lab probes—and for inline monitoring, that’s fine.
Vendors in this class typically ship from ISO 9001:2015-certified facilities; materials are commonly RoHS compliant; ingress protection depends on potting and cable gland (ask for IP details; IEC 60529 applies). Calibration traceability to NIST buffers/standards is recommended for regulated sites.
| Model | Housing | Temp Comp | Use Case |
|---|---|---|---|
| CR-102P | ABS (acid/alkali resistant) | NTC 10K | Inline process, RO, CIP |
| Generic Budget Probe | PVC | None | Basic hobby/utility checks |
| Premium Lab Probe | PEEK/Glass | PT100/1000 | High-precision benchwork |
Note: ranges and accuracy vary by controller pairing and cell constant; check final datasheets.
Food & Beverage: A Southeast Asia bottler used the CR-102P in CIP return lines; conductivity thresholds confirmed rinse endpoints, cutting water use ≈12% in month two. Hydroponics: A midwest grow swapped failing budget probes for the CR-102P; calibration held through a season, and dosing swings calmed down (their words, not mine).
Internal bench runs with 25°C KCl standards showed repeatability of ±0.5% at 1413 µS/cm and ±0.8% at 12.88 mS/cm after three temperature cycles from 15–35°C. Your mileage will vary with controller filtering and flow.
References:
Related Products
Related News


2026-11-03 04:36:32
Rotameter FAQ for small-flow measurement in water treatmentLearn how a Rotameter measures fluid flow, where it fits in water-treatment and RO systems, and which accuracy, pressure, and float details to review before ordering.
2026-10-29 03:32:11
Choosing WS 9100: Application Fit and Specification ChecksEvaluate whether the WS 9100 fits your environmental monitoring project. Review power supply options, temperature-controlled storage, sampling method compatibility, and key specifications before purchasing.
2026-10-23 04:19:53
PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering QuestionsPH/ORP-6850 FAQ: pH 0–14 and ORP ±1200 mV ranges, ±0.02 pH accuracy, isolated 4–20 mA output, relay alarms, power supply options and panel installation.
2026-07-01 09:39:59
Guide to Ensuring Water Purity for drinking water tds MonitoringEnsuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.
2026-06-29 16:58:21
Understanding the Conversion of Electrical Conductivity to TDSUnderstanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.
2026-06-27 17:38:40
Industrial Guide to Electrical Conductivity Salt Water MonitoringUnderstanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.
2026-06-26 16:42:22
Technical Guide to Industrial ec meter circuit Design and UseUnderstanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.
2026-06-25 18:39:20
Professional Guide to drinking water testing for tds and PurityDrinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.
If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.