WS9300/9350 Automatic Portable Water Sampler China Factory Suppliers

Looking for reliable water sampling solutions? The WS-9300/9350 is a professional automatic portable water sampler from leading China factory suppliers. Featuring 4C refrigerated storage, IP55 weatherproof housing, and multiple triggering modes, it ensures maximum sample integrity for wastewater and environmental monitoring.

Product Details

Product Details

Contact Now

Contact Now

Product Details

The JIRS WS-9300/9350 is a professional-grade, high-precision automatic portable water sampler engineered for the most demanding environmental and industrial monitoring applications. Designed to ensure absolute sample integrity, this rugged system integrates advanced compressed refrigeration and versatile sampling logic, making it an essential tool for wastewater treatment plants, regulatory agencies, and research institutions worldwide.

Combining industrial durability with laboratory-grade accuracy, the WS-9300/9350 supports seven flexible triggering modes and comprehensive power options. From stormwater runoff tracking and pollution source tracing to long-term unattended watershed management, this system delivers consistent, compliant results even in extreme temperatures ranging from -30°C to 40°C, ensuring your data remains reliable regardless of the field conditions.

Detailed Parameters

Sample Capacity24 Bottles x 1000 mL (PE)Screen Interface7-inch Color Touchscreen (English)
Sampling Points24 Programmable Time PointsTemperature Control(4±2)°C Compressed Refrigeration
Sampling Error±5% Volume AccuracyOperating Temp-30°C to 40°C
Protection RatingIP55 WeatherproofMTBF≥1440h / Cycle
Power OptionsAC 110V/220V, DC 12V, Car PlugDimensions/Weight711×460×571mm / Approx. 27kg

Key Advantages


Extreme Durability

IP55 rated housing and dual heating modules allow stable operation in freezing environments down to -30°C.


7 Flexible Modes

Supports flow-proportional, time-proportional, rain-gauge triggered, and more for adaptive monitoring.


Sample Integrity

Precision mechanical refrigeration at 4±2°C preserves volatile and biological analytes effectively.


Intuitive Control

7-inch high-resolution color touchscreen simplifies complex programming and real-time monitoring.


Anti-Contamination

Automatic pipe rinsing and programmable drainage prevent cross-contamination and clogging.


Smart Logging

Stores 5,000+ sampling records and 2,000+ alarm logs with full power-off data protection.

Product Gallery

Management Platforms

Adaptive Triggering

Seamlessly switch between flow, level, time, and rain-gauge triggers based on site requirements.

Automated Maintenance

Peristaltic pump lifetime reminders ensure tubing is replaced before failure occurs.

Intelligent Alarms

Water overload detection and sampling failure alarms provide immediate operational feedback.

Data Integrity

Comprehensive sampling and alarm records stored locally, safe from power outages.

Connectivity

Equipped with RS485 interface and 4-20mA analog inputs for external sensor integration.

Security Access

Customizable system passwords prevent unauthorized modifications to sampling programs.

Investment Return Comparison

Feature MetricManual SamplingWS-9300/9350 System
Labor CostHigh (Daily Site Visits)Ultra-Low (Unattended)
Sample IntegrityRisk of DegradationGuaranteed (4±2°C)
Data AccuracyHuman Error ProneHigh Precision (±5%)
Event CapturingMisses Peak EventsReal-time Triggering
ComplianceDifficult DocumentationAutomated Digital Logs

Frequently Asked Questions

Q: How does the WS-9300/9350 prevent sample contamination?

The system employs an automatic pipe rinsing function that flushes the lines before sampling, combined with programmable pre- and post-sampling drainage and filtered sampling heads to prevent sediment buildup.

Q: Can this sampler operate in extremely cold climates?

Yes, the WS-9300/9350 is designed for temperatures as low as -30°C, featuring dedicated heating modules in both the refrigerator and the pump area to ensure uninterrupted operation.

Q: What are the available power options for field deployment?

It supports three versatile power modes: AC 110V/220V for permanent installations, DC 12V tinned cords for battery use, and a standard car cigarette lighter plug for mobile sampling.

Q: How does the flow-proportional sampling mode work?

By connecting an external flow meter via the 4-20mA analog input, the sampler automatically triggers a sample based on a predefined volume of water passing through the system.

Q: Is the device protected against power outages?

Yes, the system includes power-off protection that ensures all parameter settings, system clock data, and sampling records are preserved when power is lost and restored.

Q: How is the peristaltic pump tubing maintained?

The system features a "Pump Lifetime Reminder" where users can set the operating time limit; the device then prompts the operator to replace the tubing upon expiration to maintain accuracy.

Ready to Optimize Your Water Quality Monitoring?

Contact Us

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

                  
       
                

Related Products

right
right
RO Membrane

RO Membrane

PH-6800

PH-6800

WS-9200/9250

WS-9200/9250

RO-8100

RO-8100

RO- 8200

RO- 8200

ORP-6800

ORP-6800

PH/ORP-600

PH/ORP-600

JIRS-803C

JIRS-803C

Related News

right
right
Rotameter FAQ for small-flow measurement in water treatment

Nov.03,2026

Rotameter FAQ for small-flow measurement in water treatment

Learn how a Rotameter measures fluid flow, where it fits in water-treatment and RO systems, and which accuracy, pressure, and float details to review before ordering.

Choosing WS 9100: Application Fit and Specification Checks

Oct.29,2026

Choosing WS 9100: Application Fit and Specification Checks

Evaluate whether the WS 9100 fits your environmental monitoring project. Review power supply options, temperature-controlled storage, sampling method compatibility, and key specifications before purchasing.

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

Oct.23,2026

PH/ORP-6850 Controller FAQ: Specifications, Configuration Options and Ordering Questions

PH/ORP-6850 FAQ: pH 0–14 and ORP ±1200 mV ranges, ±0.02 pH accuracy, isolated 4–20 mA output, relay alarms, power supply options and panel installation.

Guide to Ensuring Water Purity for drinking water tds Monitoring

Jul.01,2026

Guide to Ensuring Water Purity for drinking water tds Monitoring

Ensuring Water Purity: The Ultimate Guide for Drinking Water TDS Monitoring Maintaining high water quality standards is essential for public health and industrial safety. One of the most critical metrics for assessing water purity is Total Dissolved Solids TDS, which represents the combined content of all inorganic and organic substances dissolved in water. Utilizing high-precision equipment for drinking water tds measurement allows facilities to detect contamination and ensure that filtration systems are operating at peak efficiency. In this guide, we will explore the technical aspects of TDS monitoring and how advanced transmitters provide the reliability needed for modern environmental monitoring.

Understanding the Conversion of Electrical Conductivity to TDS

Jun.29,2026

Understanding the Conversion of Electrical Conductivity to TDS

Understanding the Conversion of Electrical Conductivity to TDS In water quality analysis, measuring the purity of a liquid often involves understanding the relationship between electrical conductivity to tds Total Dissolved Solids. While conductivity measures the ability of water to pass an electrical currentwhich is directly influenced by the concentration of ionized substancesTDS represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. For professionals in environmental monitoring and water treatment, mastering this conversion is essential for maintaining system efficiency and ensuring regulatory compliance.

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Jun.27,2026

Industrial Guide to Electrical Conductivity Salt Water Monitoring

Understanding Electrical Conductivity Salt Water Monitoring for Industrial Precision In the realm of water quality analysis, measuring the electrical conductivity salt water levels is a critical process for maintaining industrial efficiency and environmental safety. Conductivity serves as a direct indicator of the concentration of dissolved ions, which is essential for industries ranging from desalination plants to chemical manufacturing. Accurate monitoring prevents equipment corrosion, ensures product purity, and supports regulatory compliance. By utilizing advanced instrumentation, operators can achieve real-time insights into salt concentrations, allowing for immediate adjustments in water treatment processes to avoid costly downtime.

Technical Guide to Industrial ec meter circuit Design and Use

Jun.26,2026

Technical Guide to Industrial ec meter circuit Design and Use

Understanding the EC Meter Circuit: The Heart of Water Quality Analysis Electrical Conductivity EC is a fundamental parameter in environmental monitoring, aquaculture, and industrial water treatment. At the core of every reliable measurement device is a sophisticated ec meter circuit , which converts the physical conductance of a liquid into a precise digital reading. Whether you are managing a boilers deoxygenation process or monitoring nutrient levels in hydroponics, understanding how the circuit handles signal amplification and temperature compensation is key to ensuring data accuracy. This guide explores the technical intricacies of EC circuitry and how it integrates into professional water quality controllers.

Professional Guide to drinking water testing for tds and Purity

Jun.25,2026

Professional Guide to drinking water testing for tds and Purity

Drinking Water Testing for TDS: Ensuring Pure and Safe Water Quality Maintaining high water quality is essential for both health and industrial efficiency. When performing drinking water testing for tds , professionals seek to measure the Total Dissolved Solids TDS, which indicates the concentration of dissolved inorganic salts and organic matter in water. Whether you are managing a municipal water plant or a high-precision industrial facility, understanding the conductivity and TDS levels is the first step toward effective water treatment. In this guide, we explore the technical aspects of TDS measurement and the advanced instrumentation required for accurate monitoring.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.